This section provides two tables that indicate how the DL8000 monitors
batching status via Modbus.
B.8.1 Sequential Blending
Table B-8
lists the monitoring codes for sequential blending in manual
mode.
Table B-8. Sequential Blending Status Codes
Status
Status Name
1
Select Recipe
2
Invalid Recipe
3
Enter Preset
4
Invalid Preset
5
Batch Authorized
10
Alarm Batch Halt
12
User Batch Halt
13
Batch Complete
21
Line Pack
22
Wait for Line Pack
23
Flow Control
24
Close Valve
25
Pump Stop Delay
26
Wait for Pump Stop
27
Stop Pump
28
Wait All Stop
29
Batch Halt
30
Next Comp
31
Line Flush
32
End of Batch
33
Wait for Full Valve Close
37
End Batch
38
End Transaction
50
Select Additive
51
Request for Driver ID
53
Request for Aux 1 Data
55
Request for Aux 2 Data
57
Request for Aux 3 Data