DL8000 Preset Instruction Manual
Revised February-2016
DL8000 Keypad Display
E-69
14/02/12 13:58:59
Loaded:
250
Gal
(Status Message)
Recipe #1
Corrected: 60 deg F
Temp: 25
Vol Units: Gal
Gross: 250
Net: 248
(Status Message)
If the batch stops (“halts”) during loading due either to user intervention
or an alarm halt, one of the following screens displays:
14/02/12 13:58:59
Loaded:
899
Gal
Batch Halt
Recipe #1
Corrected: 60 deg F
Temp: 25
Vol Units: Gal
Gross: 899
Net: 890
START to Load
14/02/12 13:58:59
Loaded:
899
Gal
Alarm Halt
Recipe #1
Corrected: 60 deg F
Temp: 25
Vol Units: Gal
Gross: 899
Net: 890
No Flow 1
Note
:
If an alarm occurs during a prover batch, you
must
reset
the
alarm. Until you resolve the alarm condition, you cannot use the
keypad to switch to program mode.
Switching from
Loading Mode to
Program Mode
When batch loading completes successfully, the system automatically
shifts to program mode [63,0,9].
If an alarm halt or a user-initiated halt (from pressing
STOP
) occurs
during loading, once the batch ends the system automatically enters
program mode.
At the initiation of program mode the system checks for the following
conditions to ensure the batch is valid for proving:
SL. No.
Condition to check
valid batch
Action taken
1
Any flow alarm or
fallback alarm during
batch loading (see
note below)
Warning displays before you enter a
prover volume.
If you press
ENTER
, the system displays
a screen on which you enter the prover