![Emerson DL8000 Instruction Manual Download Page 208](http://html.mh-extra.com/html/emerson/dl8000/dl8000_instruction-manual_102194208.webp)
DL8000 Preset Instruction Manual
D-80
Communications Protocols
Revised February-2016
D.8 Status Flags Description [63,0,119]
The following table describes activities that set or reset status flags.
Table D-4. Status Flag Descriptions
Status Flag
Flag sets when…
Flag resets when…
Additive Selected
Operator selects additive through
keypad.
Note
: If TAS writes additive
selection to [63,0,60] then
flag does not change.
Transaction authorizes (in
manual mode)
Authorize Transaction
command received (in auto
mode)
Prompt Additive command
received.
Additive selection screen is
prompted (in manual mode).
Operating mode changes.
DL8000 powers on.
Clear Status command received
(in auto mode with bit 05h).
Batch Aborted (not started)
Operator presses
Stop
key for
authorized batch after entering
preset volume (in manual
mode).
Operator issues Stop Batch
command for authorized batch
which is not in progress (in auto
mode).
TAS issues End Batch
command for authorized batch
which is not in progress (in auto
mode).
DL8000 powers up for a
previously authorized batch
which was not in progress when
DL8000 powered down.
Note
: If authorized batch
was
running, flag resets.
Batch number reduces
by one.
Clear Status command received
(in auto mode with 0Eh bit).
Authorize Batch command
received (in auto mode).
Batch authorizes (in manual
mode).
Operating mode changes.
Batch Authorized
Batch authorizes (in manual
mode).
Authorize Batch command
received (in auto mode).
Batch ends (sets 0Dh).
Batch aborts.
DL8000 powers up.