![Emerson DL8000 Instruction Manual Download Page 154](http://html.mh-extra.com/html/emerson/dl8000/dl8000_instruction-manual_102194154.webp)
DL8000 Preset Instruction Manual
D-26
Communications Protocols
Revised February-2016
Reset Primary Alarms
[0x14]
Flags Immediately
Cleared
Primary Alarm active (if all active primary alarms
are cleared)
Exceptions
Passcode Entry in Progress
Operation in Manual Mode
Invalid alarm ID
Unable to reset the alarm (that is, alarm
cannot be forcibly reset) – Exception 0x5E
Supporting
Parameters
Reset alarm ID [63,0,173]
Results
As noted in description.
Display Message
[0x1C]
Displays an informational message to operator or a prompt message to get
some input data from operator.
If auxiliary data index [63,0,178] is non-zero and is less than or equal to the
number of data items [63,0,186], then the DL8000 displays a prompt to the
operator (using appropriate data prompt message
[63,0,187;189;191;193;195]) to enter/request the appropriate data item before
authorizing a new transaction.
If the transaction is not authorized and auxiliary data index [63,0,178] is
between 6 to 10, then the DL8000 displays a informational message (using
appropriate info prompt message [63,0,235;236;237;238;239]). This can be
used at the end of transaction after it is ended.
Note
: If transaction is not authorized and the Operation Timed Out flag is not
set [63,0,119], then auxiliary data 1 to 5 [63,0,188;190;192;194;196]
can be directly written, without issuing this command from TAS.
Flags Immediately Set
K&D Locked Out
Flags Immediately
Cleared
Operation Timed Out
Keypad Data Available
Exceptions
Passcode Entry in Progress
Batch in Progress
Primary Alarm active
Operation in manual mode
K&D locked out
No string data to display
Auxiliary data index [63,0,178] is zero (gives
invalid number of data items exception)
Auxiliary data index [63,0,178] is non-zero and
transaction is authorized
Auxiliary data index [63,0,178] is non-zero but
is
greater
than the number of data items
[63,0,186] and
less
than the maximum
number of data items (5).
Auxiliary data index [63,0,178] is non-zero and
not between 6 to 10