DL8000 Preset Instruction Manual
I-4
Revised February-2016
Batch Data by Component (0x10) ........... D-43
Change Operating Mode (0x37) .............. D-62
Clear Display (0x38) ................................ D-63
Clear Status (0x13) .................................. D-46
Component Totalizers (0x16) ................... D-47
Configure Recipe (0x27) .......................... D-59
Display Message (0x1C) .......................... D-51
End Batch (0x0D) ..................................... D-40
End Transaction (0x07) ............................ D-37
Enhanced Request Status (0x3C) ........... D-70
Enhanced Start Communications (0x3B) . D-68
Get Date and Time (0x28) ....................... D-60
Initialize Transaction Storage (0x20) ....... D-55
Last Key Pressed (0x31) .......................... D-61
Meter Totalizers (0x15) ............................ D-47
Prompt Additives (0x03) ........................... D-33
Prompt Preset Volume (0x08).................. D-37
Prompt Recipe (0x01) .............................. D-32
Report Alarm (0x3D) ................................ D-72
Request Command Value (0x1A) ............ D-49
Request Firmware Version (0x2A) ........... D-60
Request Keypad Data (0x1D) .................. D-52
Request Meter Values (0x19) .................. D-48
Request Power Fail Date and Time (0x1B) . D-
50
Request Preset Volume (0x09) ................ D-38
Request Program Code Values and Attributes
(0x22) ................................................... D-57
Request Selected Additives (0x04) .......... D-34
Request Selected Recipe (0x02) ............. D-32
Request Status (0x12) ............................. D-44
Request Stored Batch (0x3A) .................. D-65
Request Stored Transaction (0x39) ......... D-63
Request Transaction Storage
Status (0x1E) ....................................... D-53
Reset Primary Alarms (0x14) ................... D-46
Reset Unit (0x30) ..................................... D-61
Set Date and Time (0x29) ........................ D-60
Set Densities/Gravities (0x0B) ................. D-40
Set Program Code Value (0x23) .............. D-58
Start Communication (0x21) .................... D-56
Start/Restart Batch (0x0E) ....................... D-41
Step Batch (0x0F) .................................... D-42
Swing Arm Side (0x33) ............................ D-61
Timeout Operation (0x05) ........................ D-34
Transaction Data by Component (0x1F) .. D-54
Unauthorized Flow (0x17) ........................ D-48
Weights & Measures Switch (0x36) ......... D-62
Modbus
Authorize Batch (0x0A) ............................ D-21
Authorize Transaction (0x06) ................... D-18
Change Operating Mode (0x37) .............. D-28
Clear Display (0x38) ................................ D-28
Clear Status (0x13) .................................. D-25
Display Message (0x1C) .......................... D-26
End Batch (0x0D) ..................................... D-22
End Transaction (0x07) ............................ D-20
Prompt Additives (0x03) ........................... D-17
Prompt Preset Volume (0x08) .................. D-20
Prompt Recipe (0x01) .............................. D-16
Report Alarm (0x3D) ................................ D-29
Reset Primary Alarms (0x14) ................... D-25
Reset Unit (0x30) ..................................... D-28
Start/Restart Batch (0x0E) ....................... D-23
Stop Batch (0x0F) .................................... D-24
Timeout Operation (0x05) ........................ D-18
Set Date and Time (0x29) ............................ D-27
Protocol Frame
DanLoad 6000 .............................................. D-76
Protocols
Communication ............................................... D-1
R
Report Alarm (0x3D)
DanLoad 6000 .............................................. D-72
Modbus ......................................................... D-29
Request Command Value (0x1A)
DanLoad 6000 .............................................. D-49
Request Firmware Version (0x2A)
DanLoad 6000 .............................................. D-60
Request Keypad Data (0x1D)
DanLoad 6000 .............................................. D-52
Request Meter Values (0x19)
DanLoad 6000 .............................................. D-48
Request Power Fail Date and Time (0x1B)
DanLoad 6000 .............................................. D-50
Request Preset Volume (0x09)
DanLoad 6000 .............................................. D-38
Request Program Code Values and
Attributes (0x22) DanLoad 6000 ..................... D-57
Request Selected Additives (0x04)
DanLoad 6000 .............................................. D-34
Request Selected Recipe (0x02)
DanLoad 6000 .............................................. D-32
Request Status (0x12)
DanLoad 6000 .............................................. D-44
Request Stored Batch (0x3A)
DanLoad 6000 .............................................. D-65
Request Stored Transaction (0x39)
DanLoad 6000 .............................................. D-63
Request Transaction Storage Status (0x1E)
DanLoad 6000 .............................................. D-53
Reset Primary Alarms (0x14)
DanLoad 6000 .............................................. D-46
Modbus ......................................................... D-25
Reset Unit (0x30)
DanLoad 6000 .............................................. D-61
Modbus ......................................................... D-28
RS-232 (EIA-232) ............................................. 3-38
RS-422/485 (EIA-422/485) ............................... 3-39
RTD Module to 3-/4-Wire RTD ........................... C-5
S
Serial communications ............................. 3-39, 3-41
Set Date and Time (0x29)