Communications Protocols
D-47
Reset
Primary Alarms
[0x14]
Deviations
Some DL8000 alarms may not map directly to
DanLoad 6000 alarms.
Additional exceptions are supported such as
invalid alarm ID and Unable to reset the alarm.
DL8000 allows reset of non-primary alarms;
DanLoad 6000 allows reset of only primary
alarms.
Does not support the following DanLoad 6000
protocol alarms:
•
Data logging memory full
•
Memory Check Failure
•
Primary Display Failure
•
Secondary Display Failure
•
MPMC 1 and MPMC 2 Failure
•
Calibration Failure for all meters
•
Intermediate Level Input
Meter Totalizers
[0x15]
Returns a non-resettable authorized flow from meter. In a blending
configuration (where more than one component may flow though a meter), it
is not always possible to determine which component generates unauthorized
flow.
Flags Immediately Set
None
Flags Immediately
Cleared
None
Exceptions
None
Supporting
Parameters
Preset delivery type [63,0,29]
Results
The response frame includes the following
parameter values:
Number of meters [63,0,20]
Meter Authorized Gross Total [75,x,15]
Meter Authorized Net std or Mass Total
[75,x,17 or 18] based on delivery type
Deviations
The original DanLoad 6000-supported command
returns a snapshot of the free-running meter
totals. The DL8000 command returns free-running
authorized meter totals.
Component Totalizers
[0x16]
Returns non resettable component totalizers. In a blending configuration
(where more than one component may flow through a meter) it is not always
possible to determine which component generates unauthorized flow.
Flags Immediately Set
None
Flags Immediately
Cleared
None
Exceptions
None
Supporting
Parameters
Preset delivery type [63,0,29]