DL8000 Preset Instruction Manual
Revised February-2016
DL8000 Keypad Display
E-67
If the system finds any problems, displays an error message:
14/03/12 12:26:02
EXIT To Go Back
Flowrate Cfg Error
To resolve any configuration errors, press
EXIT
to return to the
previous screen and re-define the flow rates.
When the system verifies the configuration, it updates all values and
displays a summary screen:
14/03/12 12:26:02
Component
Meter
Sel MAX FR SetPoint
Current MF
ENTER To Continue
EXIT To Go Back
Component 1
Meter 1
Flowrate 5
500.000000
1.000000
To change any value, press
EXIT
to redisplay the set flow rate set
points screen.
If you are satisfied with the summary display of values, press
ENTER
.
The preset configures recipe 1 using the identified components 100% of
the recipe. For example, if you select component 1, the system
configures recipe 1 as:
CMP 1 = 100%
[68,0,1]
CMP 2 = 0
[68,0,2]
CMP3 = 0
[68,0,3]
CMP4 = 0
[68,0,4]
Seq. or Lo proportion = 1 [68,0,17]
Note
:
The Seq. or Lo proportion depends on the number of the
selected component. If you select component 2, the Seq. or
Lo Proportion value becomes
2
.
Additionally, the system:
Sets Unit Type [63,0,12] as 0 (“Seq. Auto”)
Sets No. of batches per transaction [63,0,126] to 0 (zero)
Sets Disable the Flush [68,0,5] to 0
Sets No. of additives [63,0,100] to 0
Sets No. of data items [63,0,186] to 0
Sets the number of info parameters [63,0,228] to 0
Sets the number of data items [63,0,186] to 0