Figure 2-3: Piping recommendations unidirectional flow
Figure 2-4: Piping recommendations bidirectional flow
All pipe lengths are minimum:
•
D = Nominal pipe size in inches (i.e. 6" pipe size; 10 D = 48 in)
•
P = Pressure measurement location
•
T = Temperature measurement location
Refer to the ultrasonic meter product data sheet for piping information. The Liquid
Ultrasonic Flow Meter Datasheet may be downloaded from the Daniel website:
www.emerson.com/en-us/automation/daniel
NOTICE
To access the product datasheet, from the Daniel products page (above link), select the
Daniel Liquid Ultrasonic Flow Meter link, click the Documentation tab, expand the Data
Sheets - Bulletins - Catalogs tab, then select the Data Sheet.
Meter tube dimensions with tube bundle or profiler plate for uni-directional and bi-
directional flow, the minimum straight pipe length is as follows:
Table 2-1: Piping recommendation for uni-directional or bi-directional flow
Uni-Directional Flow
Bi-Directional Flow
8D up stream (with a flow conditioner)
8D up stream (with a flow conditioner)
8D up stream (no flow conditioner)
8D up stream (no flow conditioner)
5D down stream
8D down stream
Installation manual
Mechanical Installation
3-9000-760
May 2019
Installation manual
35
Summary of Contents for Daniel 3814
Page 1: ...Installation manual 3 9000 760 Rev HA May 2019 Daniel 3814 Liquid Ultrasonic Flow Meter ...
Page 2: ...2 ...
Page 10: ...Contents Installation manual May 2019 3 9000 760 x 3814 Liquid Ultrasonic Flow Meter ...
Page 92: ...Configuration Installation manual May 2019 3 9000 760 92 3814 Liquid Ultrasonic Flow Meter ...
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......