Figure 2-5: High Viscosity meter tube and Venturi piping recommendations
A. Meter tube
B. Flow conditioner and flange gaskets
C. Venturi conical reducer
D. Upstream meter flange
E. 3810 Series Liquid Ultrasonic Flow Meter
F. Pressure tap
G. Temperature ap
Sunshields, to be provided by the customer, may be required to prevent exceeding the
ambient operating temperature range when the meter is mounted in a location with
extremely hot climates.
CAUTION
SUNSHIELD PROTECTION
Install a sunshield to prevent prolonged exposure to direct sunlight in extreme climates.
Failure to shield the meter may result in exceeding the process temperature range and
damage transmitter electronics.
2.4
Meter safety for hoist rings and lifting slings
A Daniel Liquid Ultrasonic Flow Meter can be safely lifted and maneuvered into and out of
a meter run for installation or service by obeying the following instructions.
Installation manual
Mechanical Installation
3-9000-760
May 2019
Installation manual
37