Table 1-2: Meter specifications
Liquid Meter specifications
Meter type
Number of paths:
•
Four path (eight transducer) chordal design
Ultrasonic type
•
Transit-time based measurement
•
Spool piece with integral mount transducers
Enclosure materials
•
ASTM B26 Gr A356.0 T6 Aluminum
—
Chromate conversion coated with a
polyurethane enamel
•
ASTM A351 Gr CF8M Stainless Steel
—
Passivated
Meter Performance
Linearity
•
± 0.15% of measured value over a 10:1
turndown
•
± 0.20% of measured value over a 20:1
turndown
Uncertainty of Meter Factor
< ± 0.027% (API MPMS, Chapter 5, Section 8,
Table B-1)
Velocity range
•
2.0 fps (0.6 m/s) to 40.0 fps (12.2 m/s)
(nominal) 48 fps (14.3 m/s) (over-range)
Upper Viscosity Limit
•
150 centipoise (Transducers LT-01, LT-03,
LT-08, LT-09)
•
1000 centipoise (Transducers LT-04, LT-05)