4. Use only the safety engineered swivel hoist rings that are rated for lifting the meter.
Do not use any other type of hoist rings with the same screw size or heavy duty
hoist rings. The meter tapping and counter bore size are suitable only for the hoist
rings specified by Daniel.
5. When installing a hoist ring, make sure the base surface of the hoist ring fully
contacts the machined flat surface of the tapped hole. If the two surfaces do not
come in contact then the hoist ring will not hold its full rated load. Torque the hoist
ring attachment bolts to the limit indicated on the hoist rings.
6. After installation of the hoist rings, always check that the ring rotates and pivots
freely in all directions.
7. NEVER attempt to lift the meter using only one hoist ring.
8. Always use separate slings to each hoist ring. NEVER reeve one sling through both
hoist rings. The slings must be of equal length. Each sling must have a load rating
that equals or exceeds the hoist ring load rating. The angle between the two slings
going to the hoist rings must never exceed 90 degrees or the load rating of the hoist
rings will be exceeded.
Mechanical Installation
Installation manual
May 2019
3-9000-760
40
3814 Liquid Ultrasonic Flow Meter