Absolute - output reports flow in both directions. For frequency outputs, Phase B of the
output is 90 degrees out of phase with Phase A.
•
Bidirectional - output reports flow on Phase A only in the forward direction and on
Phase B only in the reverse direction.
Maximum frequency for the frequency outputs
•
1000Hz
•
5000Hz
Table 3-5: Frequency/Digital Outputs possible configurations
Frequency/Digital output
Source configuration
Frequency /Digital Output 1
Frequency /Digital Output 2
Frequency /Digital Output 3
Frequency /Digital Output4
Frequency /Digital Output 5
Frequency /Digital Output 6
•
Frequency output 1A
•
Frequency output 1B
•
Digital output 1A
•
Digital output 1B
•
Frequency output 2A
•
Frequency output 2B
•
Digital output 2A
•
Digital output 2B
Output for FODO1 and Digital Output1 (Group 1 on the CPU Module) share a common
ground and have 50V isolation. FODO2 and FODO3 (Group 2 on the CPU Module) share a
common ground and have 50V isolation. This allows an output to be connected to a
different flow computer. The outputs are opto-isolated from the CPU Module and have a
withstand voltage of at least 500V rms dielectric.
Installation manual
Electrical Installation
3-9000-760
May 2019
Installation manual
61
Summary of Contents for Daniel 3814
Page 1: ...Installation manual 3 9000 760 Rev HA May 2019 Daniel 3814 Liquid Ultrasonic Flow Meter ...
Page 2: ...2 ...
Page 10: ...Contents Installation manual May 2019 3 9000 760 x 3814 Liquid Ultrasonic Flow Meter ...
Page 92: ...Configuration Installation manual May 2019 3 9000 760 92 3814 Liquid Ultrasonic Flow Meter ...
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......