68/76
MP120
5. Repeat the procedure by starting from step 3 to include another input, or press
ESC
several times to exit the
menu.
The absence of disconnected inputs in the system is signalled by the keyboard red LED E OFF.
3.13 PERIODICAL TESTS
It is recommended that you check correct operation of the antitheft system at regular intervals. Refer to the
procedures described below to check perfect operation of each system element.
Important!
: Test the MP120 system prior to any prolonged absence, e.g. prior to leaving on summer
holidays.
3.13.1 INPUT TEST
To check correct operation of the inputs, proceed as follows:
1. type in the Master code or the Installer code, then press
ENTER
twice.
2. The following message will appear on the display:
Use button ▼ to select the following menu:
Then press
ENTER
to confirm. The keyboard system status LED will start blinking.
3. Browse all the environments by actuating all the system detectors (e.g. by passing in front of volumetric
detectors and opening the doors with magnetic contacts). Every time a detector is actuated, the keyboard
buzzer will ring, and the number and name of the input in alarm condition will appear on the display.
4. Press
ESC
several times to exit the menu.
You may verify whether all the inputs have signalled an alarm with the displaying of the alarms stored (refer to
paragraph
1.4.1 stored break-in alarm displaying
). If any input (about whose actuation you are sure) has not
signalled the alarm, this may be due to the following:
•
the detector is broken;
•
the 4 minutes’ timeout has elapsed, and the test procedure has been interrupted automatically (every time an
input is actuated, the timeout will be reset to 4 minutes).
Excluded inputs are stored, yet they will generate no acoustic signals.
3.13.2 OUTPUT TEST
To check correct operation of the outputs, proceed as follows:
1. type in the Master code or the Installer code, then press
ENTER
twice.
2. The following message will appear on the display:
Use button ▼ to select the following menu:
Then press
ENTER
to confirm. The keyboard system status LED will start blinking.
3. Press
ENTER
: all the outputs (control unit and expansions) will be actuated for 5 minutes. To deactivate the
output prior to 5 seconds, press
ENTER
again.
4. Press
ESC
several times to exit the menu.
O u t p u t T e s t
E v e n t M e m o r y
I n p u t T e s t
E v e n t M e m o r y