35/76
MP120
4. The following message will appear on the display:
Press
ENTER
. If the «SpeechBoardMiss!» message appears, the SV108 voice synthesis module is not
available in the control unit.
5. Use button ▼ to choose whether to listen to «All Messages» or «Single Messages», then confirm by pressing
ENTER
.
6. If you have chosen to listen to all messages, the latter shall be played in a sequence, whereas the display will
show the type of message (Base, Break-in, etc.). Upon completion, the following will appear on the display:
7. If you have chosen to listen to the single messages, choose the desired message on the display by means of
button ▼, then press
ENTER
to play it; after the message has been played, you may select and listen to other
messages.
8. Press
ESC
several times to exit the menu.
2.14.11 NUMERIC MESSAGE CONFIGURATION
Warning! Prior to performing this procedure, make sure that the system is fully OFF.
To exchange data with the remote surveillance centres, the numeric communication protocol will need be
configured. The MP120 control unit manages the most common protocols, with the following characteristics:
Protocol
Type
Recognition
frequency
(HANDSH)
Data TX
frequency
(DATA)
Data TX
speed
(BAUD)
Format
Modifiable
ADF
DTMF
4/8/1
IDP
DTMF
Dot/Dot
S1400
DTMF
4/8/1
C200b
FSK
Dot/Dot
141910
Pulse
1400 Hz
1900 Hz
10 bps
3/1, 4/1 (or
3/2), 4/2
Extended or Non-Extended
With/without parity Ademco
slow, Silent Knight Slow
141820
Pulse
1400 Hz
1800 Hz
20 bps
3/1, 4/1 (or
3/2), 4/2
Extended or Non-Extended
With/without parity Silent
Knight Slow
231820
Pulse
2300 Hz
1800 Hz
20 bps
3/1, 4/1 (or
3/2), 4/2
Extended or Non-Extended
With/without parity Sescoa,
Franklin, DCI, Vertex
231840
Pulse
2300 Hz
1800 Hz
40 bps
3/1, 4/1 (or
3/2), 4/2
Extended or Non-Extended
With/without parity
Radionics
SIA
FSK
2300 Hz
1800 Hz
40 bps
Dot/Dot
DGF
FSK
2300 Hz
1800 Hz
40 bps
Dot/Dot
To configure the numeric telephone parameters, proceed as follows:
1. Type in the Installer code (factory setting: 000000), then press
ENTER
twice.
2. The following message will appear on the display:
Press ► until the message below appears:
Then press
ENTER
to confirm.
3. The following message will appear on the display:
C o m m u n i c a t o r P R G
E v e n t M e m o r y
P l a y m e s s a g e
P l a y m e s s a g e