16/76
MP120
If the first character is either A or B, the input will belong to an inserter or a keyboard, respectively. The inputs for
the inserters and the keyboards are identified in a different way, as shown below:
A1 = inserter 1, input 1
A2 = inserter 1, input 2
A3 = inserter 2, input 1
A4 = inserter 2, input 2
A5 = inserter 3, input 1
A6 = inserter 3, input 2
A7 = inserter 4, input 1
A8 = inserter 4, input 2
B1 = keyboard 1, input 1
B2 = keyboard 1, input 2
B3 = keyboard 2, input 1
B4 = keyboard 2, input 2
B5 = keyboard 3, input 1
B6 = keyboard 3, input 2
B7 = keyboard 4, input 1
B8 = keyboard 4, input 2
BA = keyboard 1, tamper
BB = keyboard 2, tamper
BC = keyboard 3, tamper
BD = keyboard 4, tamper
2.7.3 INPUT PROGRAMMABILITY TABLE
Programmability
Control unit
Expansion
Inserter
Keyboard
Inputs active
on a 24-h
basis
Robbery
■
■
■
■
Panic
■
■
■
■
Fire
■
■
■
■
Technological
■
■
■
■
Key input
■
Break-in input
attributes
Instant
■
■
■
■
Delayed
■
■
■
■
Final exit
■
■
■
■
Chime (gong)
■
■
■
■
2.7.4 PROGRAMMING AN INPUT
Warning! You must program all the system inputs to which detectors are connected.
To program an input, proceed as follows:
1. Type in the Installer code (factory setting: 000000), then press
ENTER
twice.
2. The display will show the message below:
Press ► until the message below appears:
Then press
ENTER
to confirm.
3. The following message will appear on the display:
Press
ENTER
to confirm.
4. The first input (“01”) will be shown on the display.
For each input, the display will show its numeric code, its type and its properties, if any (I = instant, R = delayed,
F = Final exit, C = Chime).
5. If you wish to program a different input, select the same by means of button ▼. The inputs can also be selected
by typing in the 2-digit code corresponding to the desired input. As regards the inputs for the inserters (A1...A8)
and the keyboards (B1...B8), use button
A
to type in letter A and button
S
to type in letter B. If the number of the
entered input does not exist, the nearest one will be displayed.
6. Press
ENTER
to configure the displayed input.
0 1 : B u r g l a r y n n A L L
Z o n e P r o g r a m m i n g
C o n t r . P a n e l P R G
E v e n t M e m o r y