11/76
MP120
2 – SYSTEM COMMISSIONING
2.1 SYSTEM ACCESS CODES
Up to 9 different access codes can be used to control the MP120 system: 1 Installer code, 1 Master code and 7
User codes. Each access code is made up of two parts: the user identification number (i.e. the first digit) and the
personal code (the remaining digits). The access code can be programmed freely, its length ranging from min. 3 to
max. 7 digits (including the identification number). Depending on its type, the access code guarantees access to
certain system functions. Each user may change their own access code at will.
The Master code is always enabled and is the only one code authorized to enable the other codes. Moreover, it
can resume the factory-set value of the other access codes (in the event that you forget them).
The access code must always be entered fully (including the prefix) and confirmed by pressing
ENTER
.
Warning! If an user changes the system status (from OFF to ON, or vice versa, even in part), the
installer who was identified by the system will be automatically left out. The same will occur when
using the DK key.
2.1.1 PREDEFINED CODES
Identification no.
Name
Code
Correlated sectors
Enabled
0
Installer
0 00000
All
YES
1
Master
1 11111
All
YES
2
User 2
2 22222
Programmable
NO
3
User 3
3 33333
Programmable
NO
4
User 4
4 44444
Programmable
NO
5
User 5
5 55555
Programmable
NO
6
User 6
6 66666
Programmable
NO
7
User 7
7 77777
Programmable
NO
8
User 8
8 88888
Programmable
NO
The installer code is enabled when the control unit leaves the manufacturing plant, and will be automatically
disabled when the system is actuated for the first time. In fact, the installer code is disabled every time the system
is actuated.
2.1.2 FUNCTIONS ACCESSIBLE BY THE VARIOUS CODES
Though an access code needs be entered to access the control unit functions, some functions do not require
entering a valid user code. Below is a list of this functions:
•
Language displaying
•
Logo displaying
•
Date displaying
•
Version displaying
•
System status displaying
•
Stored alarm displaying
•
Stored tampering displaying
•
Open input displaying
To access the following functions, you will have to enter any valid access code.
•
Access code change
•
System actuation/deactivation
•
Quick actuation (short code)
•
Anti-coercion alarm
To access the function below, you will have to enter a valid access code other than the INSTALLER code.
•
Time programmer pre-actuation.
To access the following functions, you will have to enter a valid access code that shall be either MASTER or
INSTALLER.
•
Input exclusion/inclusion
•
Input, output and telephone test
•
Clock programming
•
Key programming
•
Event memory file reading
•
Telephone number programming (Master enabled
only to vocal call numbers)
•
Call result displaying
•
Message listening
•
Date/time programming