Manufacturer: PPHU
EKOLOT
Type: KR-030 TOPAZ
Handling, Maintenance and Periodic Inspections
Manual
Issue: 1
Rev. N
o
:
Date: July 2010
Date:
Page
57
9.3.2.9 Removal of the elevator trimmer spring J.12.310.00.00
1. Disconnect the trimmer spring J.12.310.00.00 from the trimmer actuator
slider J.12.300.00.00 (Pic. 9.3.33, arrow „A”)
2. Unscrew the 4 bolts that fix the clamps J.12.310.04.00 to the structure.
(Pic. 9.3.33, 9.3.36 and 9.3.37)
3. Pull upward and remove the spring with the cubes.
9.3.2.10 Installation of the elevator trimmer spring J.12.310.00.00
1. Put the clamps J.12.310.04.00 on the spring J.310.00.00
2. Put the complete assembly into the hole in the rear plate of the central
tunnel, (arrow „B” in the Pic. 9.3.33) and put into the clamp
J.12.310.03.00 (Pic. 9.3.33, 9.3.35 and 9.3.36).
3. Fix the clamps with mounting bolts M5 (Pic. 9.3.37) to the plate (Pic.
9.3.33)
4. Connect the trimmer spring J.12.310.00.00 with the trimmer actuator
slider J.12.300.00.00 (Pic. 9.3.33, arrow „A”) with a bolt M5x22, a nut
and a washer (Pic. 9.3.37).
9.3.3 FLAPS DRIVE SYSTEM
9.3.3.1 Electric actuator of the flap drive system and the torsion
pipes
Pic. 9.3.38
T.12.124.00.00
T.12.124.00.00
Bolt M6x15 DIN 912
Washer
Ø
6 DIN 1440
4 x
use LOCTITE
262
T.12.210.00.00