4 Commissioning
4.12 Acyclic data
92
DX-NET-PROFINET2-2
01/22 MN040062EN
www.eaton.com
12
reserved
–
–
–
13
reserved
–
–
–
14
Value not permitted
Attempting to have write access with
a value that is within the value range,
but that is not permitted due to other
reasons (parameter with defined
values)
Subindex
✓
15
Request too long for acyclic
communication channel
The length of the current request
exceeds the maximum permitted
length of the acyclic communication
channel.
0
–
16
Parameter address not permis-
sible
Not permissible or non-supported
value for attribute, No. of elements,
parameter number, subindex, or a
combination thereof
0
✓
17
Format not permissible
Write request: Invalid format or
format not permissible for this para-
meter
0
–
18
No. of values are not consistent
Write request: The number of values
in the parameter data does not match
the number of values for the para-
meter address.
0
–
19
DO does not exist
Attempting to access a non-existing
drive object
0
✓
20
Parameter text element cannot
be changed
Attempting to have write access to a
parameter text element without write
permissions
Subindex
21
Not permissible request ID
unsupported service
✓
22
Response too long for para-
meter manager
The length of the current response
exceeds the parameter manager's
parameter processing capacity.
–
23
Multiple parameter access not
permissible
Is not supported.
✓
24, …,
64
reserved
–
–
65, …,
FF
manufacturer specific
–
–
Error
number
[hex]
Designation
Description
Supplemen-
tary infor-
mation
DC1
DE1