4 Commissioning
4.12 Acyclic data
66
DX-NET-PROFINET2-2
01/22 MN040062EN
www.eaton.com
150
0
–
–
RUN
rw
U16
ZeroSpeedHoldTime
Holding time for speed of zero
202
0
P00-29
P00-20
STOP
ro
U16
DeviceType
String: e.g., "DC1"
203
0
✓
✓
STOP
ro
UInt16
HW Version Device
Variable frequency drive hardware version
1
✓
✓
STOP
ro
UInt16
HW Version Interface
Hardware version of the interface
206
0
P00-28
P00-18
STOP
ro
S16
System Version
103
≙
1.03
1
P00-28
P00-18
STOP
ro
U16
Application version
103
≙
1.03
207
0
P00-50
-
STOP
ro
System Software Version
1
P00-50
-
STOP
ro
Application software
version
209
0
P00-30
P00-19
STOP
ro
Octet[11]
Serial number
11 byte ASCII code
1
–
–
STOP
ro
Octet[11]
Serial number A
2
–
–
STOP
ro
Octet[11]
Serial number B
3
–
–
STOP
ro
Octet[11]
Serial number C
4
–
–
STOP
ro
Octet[11]
Serial number D
210
0
P-08
P-08
STOP
rw
U16
Motor nom current
By setting the "Motor Nom Current" in the
drive, the motor overload protection is confi-
gured to match the motor rating.
The maximum value will depend on the basic
device and is always specified with one
decimal place.
Example: 14
≙
1.4 A
211
0
P-07
P-07
STOP
rw
U16
Motor rated voltage
Used to define the motor's rated operating
voltage, e.g., the voltage on the motor when
it is running at the rated frequency.
Details in Volt
215
0
–
–
STOP
rw
U16
Motor PF
216
0
P-09
P-09
-
rw
U16
Motor rated frequency
The rated frequency of the motor.
This is the frequency at which ”Motor Nom
Voltage” is applied to the motor. Details in
Hz
217
0
P-10
P-10
STOP
rw
U16
Motor rated speed
Details in rpm
218
0
P-64
P-46
STOP
rw
U16
Stator resistance
Motor stator resistance
219
0
P-65
–
STOP
rw
U16
Stator inductance
Motor leakage inductance (d)
220
0
P-66
–
STOP
rw
U16
Stator inductancePM
Motor leakage inductance (q)
221
0
–
–
STOP
rw
U16
Rotor resistance
Rotor resistance
223
0
–
–
STOP
rw
U16
Excitation current @M=0
Motor magnetizing current
224
0
–
–
STOP
rw
U16
Air gap inductance
Motor leakage factor
226
0
–
–
STOP
ro
Mutual inductance
Stator resistance (Rs)
227
0
–
–
STOP
ro
Stator resistance Meas
Stator inductance
228
0
–
–
STOP
ro
Stator inductance Meas
Rotor resistance
230
0
–
–
STOP
rw
PM-MotorSignalIn
Enable signal injection
231
0
–
–
STOP
rw
PM-MotorSignalInLevel
Signal injection level
PNU
PNU
Parameter
number
Access right
Data type
Name
Description
Index
Sub-
index
DC1
DE1
RUN/
STOP
ro/rw