D 38
Item Designation / function
108
- "Sensor error" warning lamps
A
Warning lamps 1-4 for the individual screed sections light up if a defect is
present on the corresponding sensor.
A
Check sensor. The controller operates in the emergency programme.
109
- Heater status display
A
Indicator lamps 1-4 for the individual screed section heaters light up if the
corresponding heater circuit is engaged.
A
The lamps flash when the controller requests heating for the relevant section
and this cannot be carried out at present due to a delay time or energy saving
mode.
110
- "Energy saving" indicator lamp
A
Lights up when reduced heater output (energy saving) is activated.
100
101
110
102
103
104
105
108
109
106
107
Summary of Contents for V5100TV-H
Page 2: ...www dynapac com...
Page 10: ...V 2...
Page 24: ...A 2...
Page 35: ...B 11 5 o 4 7 2 1 6 2 4 o 1 3...
Page 42: ...C 4 2 1 4 3...
Page 63: ...D 21 5 Screed heater PLC version 5 1 Switch cabinet for screed heater 40 43 44 42 41...
Page 65: ...D 23 5 2 Operating the control and monitoring unit 45 46 55 47 48 49 50 53 54 51 52...
Page 78: ...D 36 6 2 Operating the control and monitoring unit 100 101 110 102 103 104 105 108 109 106 107...
Page 94: ...D 52...
Page 100: ...E 6 Transport position 5 4 6 9 12 10 11 14 15 15 14 13...
Page 128: ...E 34 6 6 Material guide plate brace 1 2 3 3 4 6 5 7 9 8 10 11 II I 4...
Page 136: ...E 42...
Page 144: ...F 8 5 2 Guide tubes 1 1 2 2 2x 1 2...
Page 148: ...F 12 6 2 Cleaning the screed Emptying the tamper compartment 1 1 2 2 2a 1a 1a 3 4 3 4...
Page 163: ...F 27 14 2 PLC version gas heater Fuses in the switch cabinet of the screed heater A Fuses A...
Page 194: ...G 22...
Page 196: ...www dynapac com...