D 14
3.5
Exchanging the gas bottles
- Check whether the quick action valves
and both bottle valves (21) are closed.
- Unscrew the gas hoses.
- Screw the protective caps for the bot-
tle valves onto the gas bottles.
- Screw pressure reducer onto the
available mounting bracket.
f
Gas bottles that are full or not completely
emptied are under pressure.
Therefore, make sure that bottles with
their protective valve caps removed are
protected from severe impact (particu-
larly in the area of the valves or on the
valves themselves)!
- Connect new gas bottles (see the section "Connecting gas bottles and performing
a leak test").