66
c
Paper Feed Section
chap.2
(4) Elevator lower limit Switch
Description
Circuits
Operation
This is a micro switch that senses the lower limit position of the feed tray.
When the feed tray rises, the bracket disengages from the switch and the switch closes. When the feed tray
descends to its lower limit position, the bracket engages the switch’s actuator, opening the switch.
If the elevator lower limit switch does not turn ON within 30 seconds after the feed tray down command is
given, "
E002
" (Elevator lock) is displayed.
R8S02E18e
Elevator motor
R8S02052
Elevator lower
limit Switch
2
Lower limit position
Switch : OFF
Switch : ON
The actuator is
pushed.
Summary of Contents for DP-S Series