J3 pin 4
J3 represents the generator's output connector, and Pin
4 is programmable. The default setting is
Servo Alarm
.
It can be programmed to provide:
E-Stop Status
,
Overtemp Status,
or
Servo Alarm
.
J3 pin 5
J3 represents the generator's output connector, and Pin
5 is programmable. The default setting is
Home Servo
.
It can be programmed to provide:
Hold Status, Incycle Status, Incycle no Afterburst,
or
Home Servo
.
J3 pin 17
J3 represents the generator's output connector, and Pin
17 is programmable. The default setting is
Amplitude
Regulation
.
It can be programmed to provide:
Amplitude Regulation, Teaching,
or
Servo Alarm
.
Output Duration
Use the
Output Duration
function to decide on how long
the output signal should be:
Maintained
, or
100ms Pulse
The default setting is
Maintained
.
Restore System I/O Defaults
Choose this function to restore the original system input/
output defaults.
Once
Restore
is chosen, a secondary screen is displayed
asking the operator to verify the choice:
Are you sure you want to Restore I/O Defaults?
See Figure 5-52 for the screen view.
Hardware Setup, Continued from Previous Page
Hardware Setup, Continued
Figure 5–52
Restore System I/O Defaults
Page 77
Dukane Manual Part No. 403-587-00
Section 5 - Operation