5. Turn the generator
OFF
. Check the stack for proper
assembly, damaged components, or dirty mating
surfaces. Recheck the ultrasound cable for proper
connections. Repeat Steps 1 through 4. If the test still
fails, go to the next step.
6. Turn the generator
OFF
, remove the stack from the
thruster, and remove the horn from the stack. Reinstall
the transducer-booster assembly in the thruster and
turn the generator on. Repeat Steps 2 through 4.
If the assembly passes with the horn removed, the horn
is outside the specifications required for operation with
the Digi-Trac preset range. Reassemble the horn to the
stack.
The Process Settings tab of
iQ Explorer II
has a
section for Advanced Settings. These features are
designed for unique horns and applications.
See Figure 7-4a and 7-4b.
Consult Dukane Corporation before making adjustments
to these settings.
Figure 7-4a
i
Q Explorer II,
Process Settings Tab - Advanced Hardware
If any failure indications are present with the horn
removed, check the booster and the transducer for the
following
• Any visible damage
• Loose or cracked stud
• Pitted or dirty mating surfaces
Make any necessary repairs or adjustments.
Go to Step 7.
7. Repeat Steps 1 through 6.
• If the failure indications disappear, reassemble the
horn to the stack and repeat Steps 2 through 4.
• If any failure indications are still present, do not
run this stack. Return the transducer and booster
to Dukane for analysis.
Acoustic Stack Test
For more information about stacks, see this
article:
www.dukane.com/us/SE_stackarticle.htm
NOTE
Continued from Previous Page
Figure 7-4b
i
Q
Explorer II,
Advanced Process Settings Window
Page 118
iQ Series
Ultrasonic Generator/Power Supply, Servo Systems, ES User’s Manual
Dukane Manual Part No. 403-587-00
Check the "Enable Advanced Settings"
check box to enable the advanced
settings parameters. The enabled
parameters can be changed by
pressing the Advanced button to enter
the Advanced screen as shown in
Figure 7-4b.