Text Keyboard
The virtual keyboard is enabled by default, and it pops up
when required. When disabled, the virtual keyboard will
not appear.
Test at Power Up
Each time the generator is powered On, the operator
will be prompted to execute a TEST of the ultrasonics
stack. The TEST can also be cancelled. The feature can
be disabled from the Hardware Settings screen. Test at
Power Up is Enabled by default. See Figure 5-58.
The “Test at Power Up” feature can also be cancelled by
activating the “System Latch Reset” input (J2-12).
Advanced Trigger Settings
When Advanced Trigger Settings are enabled, basic trigger
settings are enhanced.
For example, in the
Process Setup
menu, when
Force
is
the Trigger Type,
Pre-trigger
is an advanced trigger func-
tion and is added to refine the
Force
selection. See Figure
5-59 on the next page where basic and advanced trigger
functions are illustrated.
Network Settings
The Network Settings screen as seen in Figure 5-59 has
five elements:
1. DHCP -
These initials stand for Dynamic Host Con-
figuration Protocol. The protocol was established for
assigning dynamic IP addresses to devices on a network.
DHCP should be enabled if connecting multiple genera-
tors when using an Ethernet router or switch.
DHCP can be enabled or disabled depending on customer
requirements.
2.
IP Address -
This
I
nternet
P
rotocol address is a num-
ber unique to a piece of equipment acting as an identifier
when the equipment is connected to a network. An IP
address is specified when a static IP is required.
3. Network Mask -
Automatically assigned by the
DHCP server.
4. Gateway Address -
Automatically assigned by the
DHCP server.
5. Network Link -
This shows the status of the connec-
tion to a network:
Linked -
This displays the speed of the network con-
nection.
Not Linked - Down
Hardware Setup, Continued from Previous Page
Hardware Setup, Continued
Figure 5–57
Buzzer Enabled
Figure 5–58
Test at Power Up
iQ 1
Test
Test at Power Up is enabled.
Please clear area around the
stack and press Test button
for 1 second before welding
parts.
Press CANCEL to abort
.
Page 81
Dukane Manual Part No. 403-587-00
Section 5 - Operation