System Status I/O
Auto Start Input
Auto Stop Input Enabled
J3 pin 4
J3 pin 5
J3 pin 17
Output Duration
Hardware Setup
Figure 5–51
System Status I/O Selections
System Status I/O
The next group of hardware settings (following the Serial
Port settings) deals with the generator's System Status I/O.
These six selections enable customizing of some of the
iQ
generator's input and output signals. Figure 5-51 shows
these functions.
Auto Start Input
Use the
Auto Start Input
function to choose one of two
types of input that can originate the Auto Start signal:
Solid State, or Mechanical
Choosing
Solid State
will have no timing delay after the
activation of the Auto Input signal. This setting is typi-
cally used when a PLC controller is used to activate the
Auto Input.
Choosing
Mechanical
will have a configurable timing
delay after the activation of the Auto Input signal. This
setting is typically used when a relay is used to activate
the Auto Input.
Choosing
Mechanical
presents another choice. That is
Switch Debounce Time
which is configurable to 5ms,
10ms or 25ms.
Auto Stop Input Enabled
This function can be disabled or enabled. The default set-
ting is
Enabled
and set to
End of Cycle
.
When
Auto Stop Input
is enabled, the operator is prompt-
ed to choose the event that causes the auto stop:
Choose either,
End of Weld
, or
End of Cycle
.
•
End of Weld
- When Auto Stop is set to
End of
Weld
, the auto stop input signal terminates the weld but
not the complete weld cycle. If hold is enabled, it begins
at the trigger of this signal.
•
End of Cycle
- When Auto Stop is set to
End
of Cycle
, the auto stop input signal terminates the
complete weld cycle (hold is not executed, even if
enabled).
Serial Port
Hardware Setup, Continued from Previous Page
Hardware Setup, Continued
Restore System I/O Defaults
Page 76
iQ Series
Ultrasonic Generator/Power Supply, Servo Systems, ES User’s Manual
Dukane Manual Part No. 403-587-00