Graph
The generator is factory programmed to provide graphs
with amplitude and power as the vertical axes.
Figure 5-67 shows the beginning graph screen.
Graph Setup
Figure 5-68 shows the graph setup screen used when se-
lecting parameters for the two
vertical
axes of the graph.
(The horizontal axis represents time.)
Select from these parameters:
Amplitude
,
Power
,
Frequency
,
Energy
,
Distance
,
Speed
,
Force
1.
Red
Axis
- Press one active soft key representing
the parameter for the vertical (red) axis. This axis is
on the left side of the graph.
2.
Blue
Axis
- Press one active soft key representing
the parameter for the vertical (blue) axis. This axis is
on the right side of the graph.
Figure 5-69 shows the graph setup screen used to choose
a starting point for the graph.
3.
Choose one of the active soft keys representing
the event that starts the graphing procedure.
The events are:
Cycle Start
,
Trigger
, or
Weld Start
.
Figure 5-70 shows the graph setup screen used to select
the end point for the graph.
4.
Chose one of the active soft keys representing one
of two events that after they have finished, the graph-
ing procedure will come to an end. The events are:
Weld End
,
Hold End
Figure 5–67
Graph Screen
Figure 5–69
Start Graph at Setup
Figure 5–68
Graph Axis Setup Screen
Figure 5–70
End Graph at Setup
Continued
NOTE
When in the graph setup screen, press
ENTER to return to the graph screen.
Page 86
iQ Series
Ultrasonic Generator/Power Supply, Servo Systems, ES User’s Manual
Dukane Manual Part No. 403-587-00