Alarm Code
Alarm Message
Explanation
Solution
U302
Auto In Switch closed at End of
Cycle
Remove active
Auto-In signal.
Verify wiring to
Auto-In signal.
U308
Generator or Press Not Ready
iQ generator initialization process is not complete.
W
ait for initialization process to complete.
Cycle power on iQ generator
.
If alarm persists, contact Dukane.
U400
W
eld Limits enabled for continu
-
ous operation
Change W
eld Mode from
Automation.
Disable W
eld Method.
U401
W
eld
Time set to Zero
Adjust weld time to be greater than zero.
U402
W
eld Power set to Zero
Adjust weld peak power to be greater than zero.
U403
W
eld Energy set to Zero
Adjust weld energy to be greater than zero.
U404
W
eld Distance set to Zero
Adjust weld distance to be greater than zero.
U405
W
eld Position set to Zero
Adjust weld position to be greater than zero.
U406
Max
Trigger
Time set to Zero
Adjust maximum trigger time to be greater than zero.
U407
Forced Shutdown
Alarm
External command was received by generator to end weld cycle.
This alarm is for information only
.
U410
Pre-trigger Overtravel
Alarm
Press travel exceeded fixed distance limit while ultrasound was active.
For servo press the distance from pre-trigger to position of trigger is required to be less than 0.25 inches or 6.35 mil
-
limeters. For pneumatic press the distance from pre-trigger to posi
-
tion of trigger is required to be less than 0.75 inches or 19.05 millimeters.
U41
1
Part Detected
Too Early
Contact between the horn and part was detected before reaching the Sensing Start Position.
Adjust Sensing Start Position to be above contact with part.
Account for variation of heights of unassembled parts. NOTE: Repeated occurrences of this alarm may result in costly damage to servo actuator
.
U413
Max
Trigger
Time Exceeded
Trigger did not occur within the speci
-
fied time limit.
Increase maximum trigger time. Start the weld process sooner
.
U414
Max
Trigger Delay
Time Ex
-
ceeded
Trigger delay distance was not reached within the specified time limit.
Increase maximum trigger delay time. Start the weld process sooner
.
U500
Servo Must Be Homed
The servo press must complete the homing process before operation is allowed.
Home the servo press by activating both operating switches.
U501
End of W
eld Signal Detected
When
Auto-stop is enabled and set for
End of W
eld, this alarm indicates that
the signal has been detected.
This alarm is for information only
.
U502
End of Cycle Signal Detected
When
Auto-stop is enabled and set for
End of Cycle, this alarm indicates that the signal has been detected.
This alarm is for information only
.
Appendix E
Menu Structure Diagrams
Figure E-1
Process Setup Menu Diagram
Process Setup
Auto
Manual
Enable
Latch on Bad Part
Initiate Mode
Disable
NOTE
Available weld choices depend
on Security access level (See
Table 4-II.) system configura-
tion, and primary weld method.
Main Menu
Position
Disabled
Energy
Secondary Weld Method
Peak Power
Trigger Type
Power
Position
Trigger Power
Trigger Position
Max Trigger Time
Start Amplitude
Teach Trigger Position
Force
Force at Trigger
Max Trigger Time
Sensing Start Position Sensing Speed
Sensing Start Position Sensing Speed
Travel Limit
Primary Weld Method
Position
Distance
Energy
Peak Power
Weld Distance
Max Weld Time
Weld Position
Weld Energy
Weld Power
Max Weld Time
Max Weld Time
Max Weld Time
Weld Profile
Static Hold Method
Time
Disable
Weld Amplitude
Afterburst
Afterburst Delay Time
Enable
Disable
Afterburst Duration
Afterburst Amplitude
Dynamic Hold Method
Enable
Disable
Distance
Until Force Reached
Dynamic Hold Speed
Hold Distance
Max Hold Time
Dynamic Hold Peak Force
Dynamic Hold Speed
Max Hold Time
Hold Time
Segmented
Constant
Constant Weld Speed
Enable Melt Detect
After Force Drops By
Speed
Enable Melt Detect
After Force Drops By
Enable
Disable
Enable
Disable
Distance Increment
Speed
Force
Advanced Servo Settings
Top of Stroke Position
Acceleration
Deceleration
Weld Motion Control
Travel Limit
Teach Top of Stroke
Teach Travel Limit
Advanced Process Settings
Free Run Frequency
Frequency Tracking
System Frequency Limits
Ramp Up Time
Frequency Lock and Hold
Ramp Down Time
Restore Advanced Process Defaults
Scan Stack
Enable
Disable
Enable
Disable
Yes
No
Wide
Normal
Narrow
Manual
NOTE
Options for Secondary Weld
Method choices are dependent
on the Primary Weld Method
choices that have been made.
Max Trigger Time
**
See
NOTE.
Trigger by Force and Trigger by
Position have Pre-trigger and
Trigger Delay Trigger features
not shown here but described on
Page 82.
NOTE
**
Page 161
Dukane Manual Part No. 403-587-00
Section 12 - Appendices