Chapter 12 Description of Parameter Settings
CP2000
12.1-02-11
51: Analog output control for RS-485 interface (InnerCOM / Modbus)
52: Output control for communication cards
53: Fire mode indication
54: Bypass fire mode indication
55: Motor 1 output
56: Motor 2 output
57: Motor 3 output
58: Motor 4 output
59: Motor 5 output
60: Motor 6 output
61: Motor 7 output
62: Motor 8 output
66: SO output logic A
67: Analog input level reached
68: SO output logic B
69: Preheating output indication
70: Fan warning detection output
Use this parameter to set the function of the multi-function terminals.
Pr.02-36–Pr.02-41 requires additional extension cards to display the parameters; the choices of
optional cards are EMC-D42A and EMC-R6AA.
The optional card EMC-D42A provides two output terminals, use with Pr.02-36–02-37.
The optional card EMC-R6AA provides six output terminals, use with Pr.02-36–02-41.
MO16–MO20 are virtual terminals, set the status of bit11–15 of Pr.02-18 to control these virtual
terminals.
Summary of function settings
(Take the normally open contact (N.O.) for example, ON: contact is closed, OFF: contact is open
Settings
Functions
Descriptions
0
No function
1
Operation indication
Active when the drive is not in STOP.
2
Operation speed
reached
Active when output frequency of the drive reaches the setting
frequency.
3
Desired frequency
reached 1 (Pr.02-22)
Active when the desired frequency (Pr.02-22) reached.
4
Desired frequency
reached 2 (Pr.02-24)
Active when the desired frequency (Pr.02-24) reached.
5
Zero Speed (frequency
command)
Active when frequency command = 0 (the drive must be in RUN
status)
6
Zero Speed, includes
Stop (frequency
command)
Active when frequency command =0 or stopped.
7
Over-torque 1
Active when the drive detects over-torque. Pr.06-07 sets the
over-torque detection level, Pr.06-08 sets the over-torque detection
time. Refer to Pr.06-06–Pr.06-08.
8
Over-torque 2
Active when the drive detects over-torque. Pr.06-10 sets the
over-torque detection level, and Pr.06-11 sets the over-torque
detection time. Refer to Pr.06-09–06-11.
Summary of Contents for CP2000 Series
Page 3: ......
Page 12: ...Chapter 1 Introduction CP2000 1 3 1 2 Model Name 1 3 Serial Number...
Page 35: ...Chapter 1 Introduction CP2000 1 26 Digital Keypad KPC CC01 Figure 1 32...
Page 42: ...Chapter 3 Unpacking CP2000 3 1 Chapter 3 Unpacking 3 1 Unpacking 3 2 The Lifting Hook...
Page 72: ...Chapter 4 Wiring CP2000 4 1 Chapter 4 Wiring 4 1 System Wiring Diagram 4 2 Wiring...
Page 77: ...Chapter 4 Wiring CP2000 4 6 Figure 4 5...
Page 79: ...Chapter 4 Wiring CP2000 4 8 This page intentionally left bank...
Page 109: ...Chapter 6 Control Terminals CP2000 6 12 This page intentionally left blank...
Page 172: ...Chapter 7 Optional Accessories CP2000 7 63 EMC filter model name EMF018A43A Figure 7 46...
Page 174: ...Chapter 7 Optional Accessories CP2000 7 65 EMC filter model name KMF370A KMF3100A Figure 7 48...
Page 175: ...Chapter 7 Optional Accessories CP2000 7 66 EMC filter model name B84143D0150R127 Figure 7 49...
Page 176: ...Chapter 7 Optional Accessories CP2000 7 67 EMC filter model name B84143D0200R127 Figure 7 50...
Page 182: ...Chapter 7 Optional Accessories CP2000 7 73 Wall Mounting Embedded Mounting...
Page 197: ...Chapter 7 Optional Accessories CP2000 7 88 6 Installation complete...
Page 237: ...Chapter 7 Optional Accessories CP2000 7 128 This page intentionally left blank...
Page 265: ...Chapter 8 Option Cards CP2000 8 28 This page intentionally left blank...
Page 277: ...Chapter 09 Specifications CP2000 9 12 575V 690V Figure 9 3 Altitude Derating Curve Figure 9 4...
Page 281: ...Chapter 09 Specifications CP2000 9 16 9 8 Efficiency Curve Figure 9 11 Figure 9 12...
Page 317: ...Chapter 10 Digital Keypad CP2000 10 36 This page intentionally left blank...
Page 361: ...Chapter 11 Summary of Parameter Settings CP2000 11 44 This page intentionally left blank...
Page 416: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 3 3 4 5...
Page 417: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 4 6 7 8...
Page 418: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 5 9 10 11...
Page 419: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 6 12 13 14...
Page 420: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 7 15 16 17...
Page 421: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 8 18 19 20...
Page 422: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 9 21 22 23...
Page 423: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 10 24 25 26...
Page 424: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 11 27 28 29...
Page 425: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 12 30 31 32...
Page 426: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 13 33 34 35...
Page 427: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 14 36 37 38...
Page 836: ...Chapter 16 PLC Function Applications CP2000 16 153...
Page 838: ...Chapter 16 PLC Function Applications CP2000 16 155...
Page 841: ...Chapter 16 PLC Function Applications CP2000 16 158 This page intentionally left blank...
Page 857: ...Chapter 17 Introduction to BACnet CP2000 17 16 This page intentionally left blank...