Chapter 09 Specifications
CP2000
9-4
460V Series
Frame
D
E
F
G
H
Model VFD_ _ _ _CP43_-_ _
750
900
1100 1320 1600 1850 2200 2800 3150 3550 4000 5000 5600 6300
*
1
Output
rating
Light duty
Rated output capacity
[kVA]
120
143
175
207
247
295
367
422
491
544
613
741
872
966
Rated output current
[A]
150*
2
180
220 260*
2
310 370*
2
460
530
616
683
770
930
1094 1212
Applicable motor
output [kW]
75
90
110
132
160
185
220
280
315
355
400
500
560
630
Applicable motor
output [HP]
100
120
150
175
215
250
300
375
425
475
536
675
745
850
Overload capacity
120% of rated output current: 1 minute for every 5 minutes
Max. output frequency
[Hz]
599
400
Carrier Frequency
[kHz]
2–10
(Default: 6)
2–9
(Default: 4)
Normal duty
Rated output capacity
[kVA]
88
120
143
175
207
247
295
367
438
491
544
690
741
872
Rated output current
[A]
110
150
180
220
260
310
370
460
550
616
683
866
930
1094
Applicable motor
output [kW]
55
75
90
110
132
160
185
220
280
315
355
450
500
560
Applicable motor
output [HP]
75
100
125
150
175
215
250
300
375
425
475
600
675
850
Overload capacity
120% of rated output current: 1 minute for every 5 minutes;
160% of rated output current: 3 seconds for every 25 seconds
Max. output frequency
[Hz]
599
400
Carrier frequency
[kHz]
2–10
(Default: 6)
2–9
(Default: 4)
Input rating
Input current
[A]
Light duty
150
180
220
260
310
370
460
530
616
683
770
930
1094 1212
Normal duty
114
157
167
207
240
300
380
400
494
555
625
866
930
1094
Rated voltage / frequency
3-phase 380–480 V
AC
[-15%– +10%], 50/60 Hz
Operating voltage range
323–528 V
AC
Frequency tolerance
47–63 Hz
Efficiency [%]
97.8
98.2
Power factor
>0.98
Drive weight [Kg]
38.5± 1.5
64.8± 1.5
86.5± 1.5
134± 4
228
Cooling method
Fan cooling
Braking chopper
Frame D–H: Optional
DC choke
Frame D–H: Built-in 3%
EMC filter
Frame D–H: Optional
NOTE
The carrier frequency is default. Increasing the carrier frequency requires a reduction in current. Please refer to Chapter
9-7 Derating Curve of Ambient Temperature.
Select the AC motor drive with capacity one grade larger for the impact load application.
Refer to Chapter 9-6 Specification for Operation Temperature and Protection Level for the protection level of each model.
*
1
The default setting is Light Duty, you can select Normal Duty and Light Duty by setting Pr.00-16.
*
2
It means the rated output current is for the models of Version B. (e.g. VFD015CP43
B
-21)
Model VFD5000CP43A-xx does not have UL certification.
Summary of Contents for CP2000 Series
Page 3: ......
Page 12: ...Chapter 1 Introduction CP2000 1 3 1 2 Model Name 1 3 Serial Number...
Page 35: ...Chapter 1 Introduction CP2000 1 26 Digital Keypad KPC CC01 Figure 1 32...
Page 42: ...Chapter 3 Unpacking CP2000 3 1 Chapter 3 Unpacking 3 1 Unpacking 3 2 The Lifting Hook...
Page 72: ...Chapter 4 Wiring CP2000 4 1 Chapter 4 Wiring 4 1 System Wiring Diagram 4 2 Wiring...
Page 77: ...Chapter 4 Wiring CP2000 4 6 Figure 4 5...
Page 79: ...Chapter 4 Wiring CP2000 4 8 This page intentionally left bank...
Page 109: ...Chapter 6 Control Terminals CP2000 6 12 This page intentionally left blank...
Page 172: ...Chapter 7 Optional Accessories CP2000 7 63 EMC filter model name EMF018A43A Figure 7 46...
Page 174: ...Chapter 7 Optional Accessories CP2000 7 65 EMC filter model name KMF370A KMF3100A Figure 7 48...
Page 175: ...Chapter 7 Optional Accessories CP2000 7 66 EMC filter model name B84143D0150R127 Figure 7 49...
Page 176: ...Chapter 7 Optional Accessories CP2000 7 67 EMC filter model name B84143D0200R127 Figure 7 50...
Page 182: ...Chapter 7 Optional Accessories CP2000 7 73 Wall Mounting Embedded Mounting...
Page 197: ...Chapter 7 Optional Accessories CP2000 7 88 6 Installation complete...
Page 237: ...Chapter 7 Optional Accessories CP2000 7 128 This page intentionally left blank...
Page 265: ...Chapter 8 Option Cards CP2000 8 28 This page intentionally left blank...
Page 277: ...Chapter 09 Specifications CP2000 9 12 575V 690V Figure 9 3 Altitude Derating Curve Figure 9 4...
Page 281: ...Chapter 09 Specifications CP2000 9 16 9 8 Efficiency Curve Figure 9 11 Figure 9 12...
Page 317: ...Chapter 10 Digital Keypad CP2000 10 36 This page intentionally left blank...
Page 361: ...Chapter 11 Summary of Parameter Settings CP2000 11 44 This page intentionally left blank...
Page 416: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 3 3 4 5...
Page 417: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 4 6 7 8...
Page 418: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 5 9 10 11...
Page 419: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 6 12 13 14...
Page 420: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 7 15 16 17...
Page 421: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 8 18 19 20...
Page 422: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 9 21 22 23...
Page 423: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 10 24 25 26...
Page 424: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 11 27 28 29...
Page 425: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 12 30 31 32...
Page 426: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 13 33 34 35...
Page 427: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 14 36 37 38...
Page 836: ...Chapter 16 PLC Function Applications CP2000 16 153...
Page 838: ...Chapter 16 PLC Function Applications CP2000 16 155...
Page 841: ...Chapter 16 PLC Function Applications CP2000 16 158 This page intentionally left blank...
Page 857: ...Chapter 17 Introduction to BACnet CP2000 17 16 This page intentionally left blank...