The unit is able to provide a digital output function in order to drive the fuel pump motor.
The fuel pump is used to transfer fuel from the large capacity main tank (if exists), to the genset daily tank
which is generally integrated in the chassis and has a limited capacity.
The fuel level reference is measured through the analog fuel level sender. When the measured fuel level
falls below
Fuel Pump Low Limit
parameter, the fuel pump output function will become active. When the
fuel level reaches
Fuel Pump High Limit
parameter, the output function will become passive. Thus the
chassis fuel tank level will be always kept between
Fuel Pump Low Limit
and
Fuel Pump High Limit
parameters.
If the
Fuel Pump High
Limit is not reached within
Fuel Filling Timer
duration, then the fuel pump will
stop for safety.
The fuel pump relay function may be assigned to any digital output using
Relay Definition
program
parameters.
The unit provides a special function for the fuel solenoid control of a gas engine.
The fuel solenoid of a gas engine is different from a diesel engine. It should be opened after the cranking
has been started and should be closed between crank cycles. The delay between the crank start and
solenoid opening is adjusted using the
Gas Solenoid Delay
program parameter.
The gas engine fuel solenoid relay function may be assigned to any digital output using
Relay Definition
program parameters.
The controller is able to provide a pre-transfer digital output function.
This function is designed for elevator systems, in order to bring the cabin to a floor and open cabin doors
before transfer.
The duration where this output is active is adjusted with the
Pre-Transfer Delay
parameter.
If the Pre-transfer Delay parameter is not zero, this will delay
transfers by the same amount.
36.18. PRE-TRANSFER SIGNAL
36.17. GAS ENGINE FUEL SOLENOID CONTROL
36.16. FUEL PUMP CONTROL
Summary of Contents for D-700 MK3
Page 50: ...D 700 MK3 User Manual Firmware V 16 8 50 5 3 3 PHASE 3 WIRE DELTA 5 2 3 PHASE 4 WIRE STAR...
Page 64: ...D 700 MK3 User Manual Firmware V 16 8 64 7 2 MAINS SYNCHRONIZATION FUNCTIONALITY...
Page 65: ...D 700 MK3 User Manual Firmware V 16 8 65 7 3 SINGLE GENSET PARALLEL WITH MAINS FUNCT...
Page 66: ...D 700 MK3 User Manual Firmware V 16 8 66 7 4 DC GENSET FUNCTIONALITY...
Page 67: ...D 700 MK3 User Manual Firmware V 16 8 67 7 5 AMF FUNCTIONALITY...
Page 68: ...D 700 MK3 User Manual Firmware V 16 8 68 7 6 ATS FUNCTIONALITY...
Page 69: ...D 700 MK3 User Manual Firmware V 16 8 69 7 7 REMOTE START FUNCTIONALITY...
Page 70: ...D 700 MK3 User Manual Firmware V 16 8 70 7 8 ENGINE CONTROL FUNCTIONALITY...
Page 71: ...D 700 MK3 User Manual Firmware V 16 8 71 7 9 REMOTE DISPLAY PANEL FUNCTIONALITY...