ED34-862
Fan Performances
FXMQ-MA
303
8
8. Fan Performances
8.1
50Hz
Note:
1. The remote controller can be used to switch between “high” and “low”.
2. The air flow is set to “standard” before leaving the factory. It is possible to switch between “standard ESP” and
“high ESP” by changing the switch in the indoor unit electrical box.
FXMQ200MA
FXMQ250MA
High
Low
High
Low
(Pa)
58
(High ESP)
100
300
65
48
200
63
(Standard ESP)
0
(High ESP)
50
30
20
10
0
30
20
10
0
53
50Hz 220V
(Standard
ESP)
Exte
rnal
sta
tic
p
ressu
re
(mmH
2
O)
(mmH
2
O)
Air flow
(m
3
/min)
Upper
lim
it
of
ESP
(High
ESP)
Upper limit of ESP
(Standard ESP)
Low
er limit of ESP
(High ESP)
Lower limit of ESP
(Standard ESP)
3D035172-5
(Pa)
0
200
100
300
10
20
0
30
10
20
0
30
80
72
60
75
62
65
50Hz 220V
Exte
rn
al
sta
ti
c
p
ressu
re
(mmH
2
O)
(mmH
2
O)
Air flow
(m
3
/min)
Low
(High ESP)
High
(High ESP)
Upper
lim
it
of
ESP
(High ESP)
Upper limit of ESP
(Standard ESP)
Low
(Standard ESP)
Lower limit of ESP
(Standard ESP)
High
(Standard
ESP)
Lo
wer limit of ESP
(High ESP)
3D035173-5