Wiring Diagrams
ED34-862
322
FXHQ-MA
5. Wiring Diagrams
FXHQ32 · 63 · 100MAVE
N
F1
(DEFR
OST
-ORANGE)
A1P
LIGHT EMITTING DIODE
X6A
CONNECT
OR FOR OPTIONAL P
AR
TS
ELECTRICAL APPENDICES)
L
X2A
X27A
X8A
REMO
TE CONTR
OLLER
X2M
A2P
SS1
RED
THERMIST
OR (AIR)
ELECTRIC P
AR
TS BO
X
WHT
R2T
X1M
INPUT FR
OM
X23A
KAR
LIMIT SWITCH (SWING FLAP)
NO
TE-3
C1R
BLK
PO
WER SUPPL
Y
F2
SS1
X23A
X1A
X18A
T2
MO
T
OR (INDOOR F
AN)
WHT
RED
NO
TE-6
BLU
CAP
A
CIT
OR (M1F)
X7A
MO
T
OR (DRAIN PUMP)
M
Q1M
R3T
NO
TE-5
A1P
TERMINAL BLOCK (PO
WER)
X1A
X23A
TERMINAL
BLOCK
(CONTR
OL)
LIGHT EMITTING DIODE
PHASE CONTR
OL CIRCUIT
X8A
TRANSMISSION
X12A
SS2
YL
W
P2
MSW
X11A
WIRING CENTRAL
P2
SS2
(OPTIONAL A
CCESSOR
Y)
H4P
BLK
Y1E
WHT
WHT
INDOOR UNIT
THERMIST
OR (COIL GAS)
SELECT
OR SWITCH (MAIN/SUB)
A3P
(TIMER-GREEN)
LIGHT EMITTING DIODE
X30A
A1P
R1T
X2M
ORG
NO
TE-4
F1U
M
X9A
X3A
N
F2
H3P
P2
M
X1A
CONNECT
OR
(WIRING
AD
APT
OR
FOR
PRINTED CIRCUIT BO
ARD
F1
PNK
THERMIST
OR (COIL LIQ
UID)
P1
CONNECT
OR (FLO
A
T SWITCH)
ELECTR
ONIC
EXP
ANSION
VAL
VE
WIRED REMO
TE CONTR
OLLER
MA
GNETIC RELA
Y (M1P)
CONNECT
OR (WIRELESS
T1
THERMO
SWITCH
(M1F
EMBEDDED)
LIGHT EMITTING DIODE
T2
PC
LIGHT
EMITTING
DIODE
(ON-RED)
BS1
(WIRELESS ADDRESS SET)
OUTSIDE
X1M
220-240V
~
50Hz
SS1
C1R
PRINTED CIRCUIT BO
ARD
X13A
P1
t˚
P1
X25A
X4A
TO
WIRELESS
REMO
TE
CONTR
OLLER)
MA
GNETIC RELA
Y (M1S)
H4P
T1R
SELECT
OR
SWITCH
(MAIN/SUB)
X18A
T1R
H2P
R1T
(WIRELESS REMO
TE CONTR
OLLER)
RECEIVER/DISPLA
Y UNIT
WIRED REMO
TE CONTR
OLLER
THERMIST
OR (AIR)
KPR
HAP
S1Q
RECEIVER/DISPLA
Y
UNIT
(A
TT
A
CHED
L
PUSH B
UTT
ON (ON/OFF)
TRANSFORMER
(220-240V/22V)
REMO
TE CONTR
OLLER)
SELECT
OR SWITCH
H1P
BLK
RED
YL
W
MO
T
OR (SWING FLAP)
PRINTED CIRCUIT BO
ARD
(SER
VICE MONIT
OR-GREEN)
WHT
(FIL
TER SIGN-RED)
FUSE( B , 5A, 250V)
M1S
H3P
M1F
T1
M1P
X23A
X18A
)
(
X8A
1.
:
TERMINAL BLOCK , :
CONNECT
OR
:
SHOR
T CIRCUIT CONNECT
OR
2.
:
FIELD
WIRING
3.
IN CASE USING CENTRAL REMO
TE CONTR
OLLER,
CONNECT IT
T
O
THE UNIT IN A
CCORD
ANCE
WITH
THE A
TT
A
CHED INSTR
UCTION MANU
AL.
4.
X23A IS CONNECTED
WHEN
THE
WIRELESS REMO
TE
CONTR
OLLER KIT IS BEING USED
.
5.
WHEN CONNECTING
THE INPUT
WIRES FR
OM OUTSIDE,
FORCED OFF OR ON/OFF CONTR
OL OPERA
TION CAN BE
SELECTED BY REMO
TE CONTR
OLLER.
IN DET
AILS
, REFER
T
O
THE INST
ALLA
TION MANU
AL A
TT
A
CHED
THE UNIT
.
6.
IN CASE INST
ALLING
THE DRAIN PUMP
, REMO
VE
THE
SHOR
T CIRCUIT CONNECT
OR OF X8A AND EXECUTE
THE
ADDITIONAL
WIRING FOR FLO
A
T SWITCH AND DRAIN PUMP
.
7.
SYMBOLS SHO
W AS FOLLO
WS
.
PNK :
PINK
WHT :
WHITE
YL
W :
YELLO
W ORG :
ORANGE
BLU :
BLUE BLK :
BLA
CK RED :
RED
8.
USE COPPER CONDUCT
ORS ONL
Y
.
NO
TES)
t˚
t˚
t˚
A1P
C1R
F1U
HAP
KAR
KPR
M1F
M1S
Q1M
R1T
R2T
R3T
S1Q
T1R
X1M
X2M
Y1E
PC
M1P
R1T
SS1
A2P
A3P
BS1
H1P
H2P
220V
~
60Hz
~
~
~
OPTIONAL P
AR
TS
3D039801D