ESIE13-03
|
Part 2. Troubleshooting
4. Component checklist
Page 54
13/05/15
|
Version 2.0
Ground source heat pump
4. Component checklist
Overview of component checklists:
4.1. Required tools for component check
Figure 1 - Required tools for component check
4.2. Backup heater E1H, E2H
Not applicable
Required tools for component check ..............................................54
Backup heater E1H, E2H ............................................................... 54
Thermistors R1T, R2T, R3T, R4T, R5T, R6T, R10T ........................58
Safety valve SV1, SV2 (pressure relief valve)................................61
Expansion vessel EXP1, EXP2 ......................................................62
Brine flow switch S1L .....................................................................63
Brine pump M3P.............................................................................64
Water pump M1P............................................................................66
Plate type heat exchanger PHE1, PHE2 ........................................67
Compressor M1C............................................................................69
High pressure sensor B1PH ...........................................................70
High pressure switch S1PH ............................................................71
Electronic expansion valve K1E .....................................................72
Thermal protector backup heater Q1L............................................73
Inverter PCB A10P .........................................................................75
Water flow sensor B1L....................................................................77
3-way valve M3S ............................................................................79
1. Magnet (tool part N° 9950038)
3. Inverter analyzer (tool part N° 1368521)
2. Extension cable (tool part N° 5011856)
Technical specification
Description
The 2-stage backup heater is composed of heater E1H (3 x 1 kW) and E2H
(3 x 2 kW).
The backup heater is used to assist the heat
pump system to heat the water for space heating
and domestic hot water operation.
Location
Piping diagram
Switch box
Unit
Check procedure
Mechanical check
1
2
3
Water side