ESIE13-03
|
Part 3. Repair
2. Unit specific repair procedures
Page 88
13/05/15
|
Version 2.0
Ground source heat pump
Figure 7 - Draining the water circuit
2.1.6. Air purge of the space heating circuit
To perform an air purge, refer to “9.3 Air purge function on the space heating circuit” in the Daikin Altherma ground source heat
pump Installer reference guide.
2.1.7. Draining the domestic hot water tank
2.1.7.1 Procedure
To drain the domestic hot water tank, refer to “To drain the domestic hot water tank” in the Daikin Altherma ground source heat
pump Installer reference guide.
2.1.8. Removing the top panel
1. Switch off the Daikin Altherma GSHP via the user interface.
2. Loosen and remove the 4 screws (1) that fix the top panel.
3. Remove the top panel (2) from the Daikin Altherma GSHP.
Figure 8 - Removing the top panel
1. Water circuit drain
2. Water circuit drain valve DR4
1. Screw
2. Top panel
1
2
2
2
1
2
2