ESIE13-03
|
Part 3. Repair
2. Unit specific repair procedures
Page 118
13/05/15
|
Version 2.0
Ground source heat pump
Figure 35 - Replacing the water pump - 3
17. Loosen the nuts (1) that fix the water pump (3) to the pressure relief valve.
18. Remove the water pump (3).
19. Remove the seals (2) from the nuts (1).
1. Pivoting power input section
6. Water pressure relief valve
2. Lower nut
7. Clip
3. Corrugated pipe
8. Water pump
4. Seal
9. Backup heater
5. Nut (water manometer)
10. Support
7
1
10
9
8
4
3
4
2
5