Field Setting
ESIE09-08A
102
Test Operation
[6] Option setup
[6-00]
Domestic hot water tank option
If the domestic hot water tank is installed, its operation must be enabled by field setting. Default [6-
00] = 0 which means no tank is installed. Set [6-00] to 1 if the optional domestic hot water tank is
installed.
Note :
When enabling the domestic hot water tank option be aware that the advised default settings become
active:
[1-00]
= 1 = automatic night storage
[4-00]
= 1 = disinfection function
[6-01]
External room thermostat option
If the optional external room thermostat is installed, its operation must be enabled by field setting.
Default [6-01] = 0, which means no external room thermostat is installed. Set [6-01] to 1 if the
optional external room thermostat is installed.
The external room thermostat only gives an ON/OFF signal to the heat pump based on the room
temperature. Because it does not give continuous feedback information to the heat pump, it is
supplementary to the remote controller room thermostat function. To have a good control of the
system and avoiding frequent ON/OFF it is advised to use the automatic weather dependent set point
operation.
Note :
By using an external room thermostat, the smart logic of the standard remote controller is overruled.
[6-02]
Heater kit
Once installed, you can activate the heater kit by changing field setting [6-02]=1.
From that moment on, the heat pump system will take the heater kit into account whilst deciding
operation. When the heater is actually operating, the heater symbol is shown on the remote controller.
There is no step 1-2 indication.
For more information see “Part 9 - External Backup Heater Kit” on page 255.
[6-03]
Solar support
For more information refer to the EKHWP installation manual.
[6-04]
Benefit kWh rate power supply mode
If benefit kWh rate power supply is used, the mode must be selected. Default [6-04] = 0 which means
no benefit kWh rate power supply is used.
Set [6-04] to 1 to use benefit kWh rate power supply mode 1 (normally closed contact which will
open when the power supply is interrupted), or set [6-04] to 2 to use benefit kWh rate power supply
mode 2 (normally opened contact which will close when the power supply is interrupted).
First
code
Second
code
Setting name
Default
value
Range
Step
Unit
6
Option setup
00
Domestic hot water tank installed
0 (OFF)
0/1
—
—
01
Optional room thermostat installed
0 (OFF)
0/1
—
—
04
Benefit kWh power supply mode
0
0/2
1
—
Summary of Contents for ALTHERMA HT EKBUHAA6 V3
Page 2: ......
Page 7: ...ESIE09 08A Table of Contents v 1 3 Service Tools 283 Index i Drawings Flow Charts iii ...
Page 16: ...Model Names of Indoor Outdoor Units Tanks ESIE09 08A 4 General Information ...
Page 28: ...Refrigerant Circuit ESIE09 08A 16 Refrigerant Circuit EKHBRD 011 014 016 AB AC V1 Y1 ...
Page 40: ...Functional Parts Layout ESIE09 08A 28 Refrigerant Circuit ...
Page 63: ...ESIE09 08A PCB Layout for EKHBRD 011 014 016 AA AB AC V1 Y1 Refrigerant Circuit 51 ...
Page 64: ...PCB Layout for EKHBRD 011 014 016 AA AB AC V1 Y1 ESIE09 08A 52 Refrigerant Circuit ...
Page 125: ...ESIE09 08A Field Setting Test Operation 113 ...
Page 232: ...Troubleshooting by Indication on the Remote Controller ESIE09 08A 222 Troubleshooting ...
Page 237: ...ESIE09 08A Piping Diagrams Appendix 227 EKHBRD 011 014 016 AB AC V1 Y1 ...
Page 250: ...Wiring Diagrams ESIE09 08A 240 Appendix EKHBRD 011 014 016 AB AC V1 ...
Page 251: ...ESIE09 08A Wiring Diagrams Appendix 241 ...
Page 256: ...Wiring Diagrams ESIE09 08A 246 Appendix EKHBRD 011 014 016 AB AC Y1 ...
Page 257: ...ESIE09 08A Wiring Diagrams Appendix 247 ...
Page 260: ...Wiring Diagrams ESIE09 08A 250 Appendix ...