6
|
Application guidelines
Installer reference guide
51
EWSAH/X06D
Daikin Altherma 3 WS
4P675764-1 – 2022.04
b
b1
Power meter 1 (1N~ or 3N~ depending on the backup
heater)
b2
Power meter 2 (1N~)
For details about connecting the power meters to the unit, see
"9.2.4 To connect the electricity meters"
94].
c
Compressor (1N~)
d
Hydro (1N~)
e
Backup heater (1N~ or 3N~)
C1
~
C5
For details about
C1
~
C5
, see
"9.2.1 To connect the main power
86].
F1B
~
F3B
Overcurrent fuse
S1S
Preferential kWh rate power supply contact
6.6 Setting up the power consumption control
You can use the following power consumption controls. For more information
about the corresponding settings, see
195].
#
Power consumption control
1
"6.6.1 Permanent power limitation"
▪
Allows you to limit the power consumption of the entire heat pump
system (sum of indoor unit and backup heater) with one permanent
setting.
▪
Limitation of power in kW or current in A.
2
"6.6.2 Power limitation activated by digital inputs"
▪
Allows you to limit the power consumption of the entire heat pump
system (sum of indoor unit and backup heater) via 4 digital inputs.
▪
Limitation of power in kW or current in A.
3
"6.6.4 Current limitation by current sensors"
▪
Allows you to limit the current of the household by limiting the current of
the heat pump system (sum of indoor unit and backup heater).
▪
Limitation of current in A.
4
"6.6.5 BBR16 power limitation"
▪
Restriction:
Only available in Swedish language.
▪
Allows you to comply with BBR16 regulations (Swedish energy
regulations).
▪
Limitation of power in kW.
▪
Can be combined with the other power consumption controls. If you do
so, the unit uses the most restrictive control.