14 Maintenance and service
NOTICE
Maintenance MUST be done by an authorised installer or service agent.
We recommend performing maintenance at least once a year. However, applicable
legislation might require shorter maintenance intervals.
NOTICE
Applicable legislation on
fluorinated greenhouse gases
requires that the refrigerant
charge of the unit is indicated both in weight and CO
2
equivalent.
Formula to calculate the quantity in CO
2
equivalent tonnes:
GWP value of the
refrigerant × total refrigerant charge [in kg] / 1000
In this chapter
14.1 Maintenance safety precautions
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
NOTICE: Risk of electrostatic discharge
Before performing any maintenance or service work, touch a metal part of the unit in
order to eliminate static electricity and to protect the PCB.
14.2 Yearly maintenance
14.2.1 Yearly maintenance: overview
▪
Central water loop circuit leakage
▪
Chemical disinfection
▪
Descaling
▪
Drain hose
▪
Fluid pressure of space heating and central water loop circuit
▪
Pressure relief valves (1 at central water loop side, 1 at space heating side)
▪
Pressure relief valve of the domestic hot water tank
▪
Switch box