8/11
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.I
[2-0D]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.I
[2-0E]
R/W
20~50 A, step: 1 A
50 A
9.I
[3-00]
R/W
0: No
1: Yes
9.I
[3-01]
0
9.I
[3-02]
1
9.I
[3-03]
4
9.I
[3-04]
2
9.I
[3-05]
1
9.I
[3-06]
R/W
18~30°C, step: 0,5°C
30°C
9.I
[3-07]
R/W
12~18°C, step: 0,5°C
12°C
9.I
[3-08]
R/W
25~35°C, step: 0,5°C
35°C
9.I
[3-09]
R/W
15~25°C, step: 0,5°C
15°C
9.I
[3-0A]
R/W
0: OFF
1: Every Day
2: Every Week
9.I
[3-0B]
R/W
30~120 minutes, step: 30 minutes
60 minutes
9.I
[4-00]
R/W
0: Disabled
1: Enabled
2: Only DHW
9.I
[4-01]
R/W
0: None
1: BSH
2: BUH
9.I
[4-02]
R/W
14~35°C, step: 1°C
16°C
9.I
[4-03]
3
9.I
[4-04]
R/O
0: Intermittent
1: continuous
2: Disabled
9.I
[4-05]
0
9.I
[4-06]
R/W
0: Manual
1: Automatic (normal SH/ DHW ON)
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
9.I
[4-07]
R/W
[5-0D]=2: 0~9 kW, step: 1 kW
9 kW
[5-0D]
≠
2: 0~6 kW, step: 1 kW
6 kW
9.I
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
3: Current sensors
9.I
[4-09]
R/W
0: Current
1: Power
9.I
[4-0A]
1
9.I
[4-0B]
R/W
1~10°C, step: 0,5°C
1°C
9.I
[4-0D]
R/W
1~10°C, step: 0,5°C
3°C
9.I
[4-0E]
R/W
-6~6 A, step: 0,5 A
0 A
9.I
[5-00]
R/W
0: No
1: Yes
9.I
[5-01]
R/W
-15~35°C, step: 1°C
0°C
9.I
[5-02]
R/W
0: Disabled
1: Enabled
9.I
[5-03]
R/W
-15~35°C, step: 1°C
0°C
9.I
[5-04]
10
9.I
[5-05]
R/W
0~50 A, step: 1 A
16 A
9.I
[5-06]
R/W
0~50 A, step: 1 A
16 A
9.I
[5-07]
R/W
0~50 A, step: 1 A
16 A
9.I
[5-08]
R/W
0~50 A, step: 1 A
16 A
9.I
[5-09]
R/W
0~20 kW, step: 0,5 kW
5 kW
9.I
[5-0A]
R/W
0~20 kW, step: 0,5 kW
5 kW
9.I
[5-0B]
R/W
0~20 kW, step: 0,5 kW
5 kW
9.I
[5-0C]
R/W
0~20 kW, step: 0,5 kW
5 kW
9.I
[5-0D]
R/W
0: 230V, 1~
2: 400V, 3~
9.I
[5-0E]
1
9.I
[6-00]
R/W
2~20°C, step: 1°C
6°C
9.I
[6-01]
R/W
0~10°C, step: 1°C
2°C
9.I
[6-02]
0
9.I
[6-03]
3
9.I
[6-04]
6
9.I
[6-05]
0
9.I
[6-06]
0
9.I
[6-07]
0
What emitter type is connected to the main LWT zone?
What emitter type is connected to the additional LWT zone?
What is the maximum allowed current over the heatpump ?
Is auto restart of the unit allowed?
--
--
--
--
--
What is the maximum desired room temperature in heating?
What is the mimimum desired room temperature in heating?
What is the maximum desired room temperature in cooling?
What is the minimum desired room temperature in cooling?
What is the BUH operation mode?
Which electric heater has priority?
Below which outdoor temperature is heating allowed?
--
Water pipe freeze prevention
--
Emergency setting
Which power limitation mode is required on the system?
Maximum BUH capacity
What is the requested limit for DI3?
Which power limitation type is required?
--
Automatic cooling/heating changeover hysteresis.
Automatic cooling/heating changeover offset.
Equilibrium: Deactivate backup heater (or external backup heat source in case of a
bivalent system) above the equilibrium temperature for space heating?
What is the equilibrium temperature for the building?
Current sensor offset
Backup heater voltage
--
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
Space heating priority.
Space heating priority temperature.
--
What is the requested limit for DI1?
What is the requested limit for DI2?
--
--
What is the requested limit for DI4?
What is the requested limit for DI1?
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
--
--
--
--
Waterloop Valve Opening Frequency
Waterloop Valve Opening Duration