11
|
Configuration
Installer reference guide
188
EWSAH/X06D
Daikin Altherma 3 WS
4P675764-1 – 2022.04
#
Code
Description
[8.A]
N/A
Reset the MMI EEPROM
to factory default
Possible read-out information
In menu…
You can read out…
[8.1]
Energy data
Produced energy, consumed electricity,
and consumed gas
[8.2]
Malfunction history
Malfunction history
[8.3]
Dealer information
Contact/helpdesk number
[8.4]
Sensors
Room, tank or domestic hot water,
outside, and leaving water temperature
(if applicable)
[8.5]
Actuators
Status/mode of each actuator
Example:
Domestic hot water pump
ON/OFF
[8.6]
Operation modes
Current operation mode
Example:
Defrost/oil return mode
[8.7]
About
Version information about the system
[8.8]
Connection status
Information about the connection
status of the unit, the room thermostat
and the LAN adapter.
11.5.9 Installer settings
Configuration wizard
After first power ON of the system, the user interface will guide you using the
configuration wizard. This way you can set the most important initial settings. This
way the unit will be able to run properly. Afterwards, more detailed settings can be
done via the menu structure if required.
To restart the configuration wizard, go to
Installer
settings
>
Configuration wizard
[9.1].
Domestic hot water
Domestic hot water
The following setting determines if the system can prepare domestic hot water or
not, and which tank is used. This setting is read only.
#
Code
Description
[9.2.1]
[E‑05]
(a)
[E‑06]
(a)
[E‑07]
(a)
▪
No DHW
(domestic hot water)
▪
Integrated
The backup heater will also be used for
domestic hot water heating.
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
•
[E-05]: Can the system prepare domestic hot water?
•
[E-06]: Is a domestic hot water tank installed in the system?
•
[E-07]: What kind of domestic hot water tank is installed?