10
|
LAN adapter
Installer reference guide
108
EWSAH/X06D
Daikin Altherma 3 WS
4P675764-1 – 2022.04
b2
Solar inverter/energy management system
b3
Solar panels
C
See
c1
Electricity meter
c2
Electrical grid
10.1.2 System requirements
The requirements posed on the heat pump system depend on the LAN adapter
application/system layout.
App control
Item
Requirement
LAN adapter software
It is recommended to ALWAYS keep the LAN adapter
software up-to-date.
Unit control method
On the user interface, make sure to set [2.9]=2
(
Control
=
Room thermostat
)
Smart Grid application
Item
Requirement
LAN adapter software
It is recommended to ALWAYS keep the LAN adapter
software up-to-date.
Unit control method
On the user interface, make sure to set [2.9]=2
(
Control
=
Room thermostat
)
Domestic hot water
settings
To allow for energy buffering in the domestic hot
water tank, on the user interface, make sure to set
[9.2.1]=4 (
Domestic hot water
=
Integrated
).
Power consumption
control settings
On the user interface, make sure to set:
▪
[9.9.1]=1 (
Power consumption control
=
Continuous
)
▪
[9.9.2]=1 (
Type
=
kW
)
INFORMATION
For instructions on how to perform a software update, see
10.1.3 On-site installation requirements
What you need on site to install the LAN adapter depends on the system layout.
BRP069A61
BRP069A62
Always
PC/laptop with Ethernet connector
Router (DHCP enabled)
Smartphone with the ONECTA app
Depending on the system layout
IF
connection to an
electricity meter (X2A)
Electricity meter
—
2‑wire cable
—