EWSAH/X06D
Daikin Altherma 3 WS
4P675764-1 – 2022.04
#
Code
Description
[9.9.E]
[4-0E]
Current sensor offset
: Offset on the
household current measured by the current
sensors.
–6 A~6 A, step 0.5 A
Priority heater
This setting defines the priority of the electrical heaters depending on applicable
limitation. As no booster heater is present, the backup heater will always be
prioritised.
#
Code
Description
[9.9.D]
[4-01]
Priority heater
:
▪
0
None
: The backup heater is prioritised.
▪
1
Booster
heater
: After restart, the
setting will be reverted back to 0=
None
and
the backup heater will be prioritised.
▪
2
Backup heater
: The backup heater is
prioritised.
BBR16
See
"6.6.5 BBR16 power limitation"
55] for detailed information about this
functionality.
INFORMATION
Restriction:
BBR16 settings are only visible when the language of the user interface is
set to Swedish.
NOTICE
2 weeks to change.
After you activated BBR16, you only have 2 weeks to change its
settings (
BBR16 activation
and
BBR16 power limit
). After 2 weeks, the unit
freezes these settings.
Note:
This is different from the permanent power limitation, which is always
changeable.
BBR16 activation
#
Code
Description
[9.9.F]
[7-07]
BBR16 activation
:
▪
0:
disabled
▪
1:
enabled
BBR16 power limit
#
Code
Description
[9.9.G]
[N/A]
BBR16 power limit
: This setting can only
be modified via the menu structure.
▪
0 kW~25 kW, step 0.1 kW