10
|
LAN adapter
Installer reference guide
106
EWSAH/X06D
Daikin Altherma 3 WS
4P675764-1 – 2022.04
Status LEDs
LED
Description
Behaviour
LD1
Indication of power to the
adapter, and of normal
operation.
▪
LED
flashing:
normal
operation.
▪
LED
NOT
flashing:
no
operation.
LD2
Indication of TCP/IP
communication with the
router.
▪
LED
ON:
normal
communication.
▪
LED flashing: communication
problem.
LD3
Indication of communication
with the indoor unit.
▪
LED
ON:
normal
communication.
▪
LED flashing: communication
problem.
LD4
Indication of Smart Grid
activity.
▪
LED ON: system running in
the "Recommended ON",
"Forced ON", or "Forced OFF"
Smart Grid operation mode.
▪
LED OFF: system running in
the
"Normal
operation"
Smart Grid operation mode,
or
operating
in
normal
operation conditions (space
heating/cooling, production
of domestic hot water).
▪
LED flashing: LAN adapter
performing a Smart Grid
compatibility check.
INFORMATION
▪
The DIP switch is used to configure the system. For more information, see
"10.4 Configuration – LAN adapter"
▪
When the LAN adapter performs a Smart Grid compatibility check, LD4 flashes.
This is NOT erroneous behaviour. After a successful check, LD4 will either stay ON
or go OFF. When it keeps flashing for more than 30 minutes, the compatibility
check failed, and NO Smart Grid operation is possible.
10.1.1 System layout
Integrating the LAN adapter into the heat pump system allows for the following
applications:
▪
App control (only)
▪
Smart Grid application (only)
▪
App c Smart Grid application