9
|
Electrical installation
Installer reference guide
87
EWSAH/X06D
Daikin Altherma 3 WS
4P675764-1 – 2022.04
#
Layout
Open the unit
(a)
3 Single cable power supply (= combined power
supply)
+
Preferential kWh rate power supply without
separate normal kWh rate power supply
(b)
C1
C2
X5M
C1
: Preferential kWh rate power supply (1N~ or
3N~)
C2
: Preferential kWh rate power supply contact
1
3
2
4 Dual cable power supply (= split power supply)
+
Preferential kWh rate power supply without
separate normal kWh rate power supply
(b)
C1
C5
C2
X5M
C1
: Preferential kWh rate power supply for the
backup heater (1N~ or 3N~)
C2
: Preferential kWh rate power supply contact
C5
: Preferential kWh rate power supply for the
rest of the unit (1N~)
3
2
1
5
4
5 Single cable power supply (= combined power
supply)
+
Preferential kWh rate power supply with separate
normal kWh rate power supply
(b)
NOT ALLOWED
—