background image

PFD1/PFS1 – OPERATING INSTRUCTIONS

 

INDEX 

DATE 

N° 

03 

27/09/01 

DC01020US 

 

 
 
 
 
 
 
 
 
 
 
 

PUMP 

 

PFD1/PFS1 

 

OPERATING INSTRUCTIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SAINT-GOBAIN PERFORMANCE PLASTICS ASTI    SAINT-GOBAIN PERFORMANCE PLASTICS ASTI

 

(Headquarters) 

(Factory) 

41, boulevard des Bouvets 

E.A.D.A.C. des Berthilliers 

F-92741 NANTERRE CEDEX 

F-71850 CHARNAY LES MACON 

Tel:   33. (0) 1.55.68.59.59 

Tel: 33. (0) 3.85.20.27.00 

Fax: 33. (0) 1.55.68.59.68 

Fax: 33. (0) 3.85.29.18.48 

 

SAINT-GOBAIN PERFORMANCE PLASTICS

 

7301 Orangewood Avenue 

GARDEN GROVE, CA 92841 

Phone: 1 (714) 630 5818 

Fax: 1 (714) 688 2416 

 

http://www.astipure.com - http://www.plastics.saint-gobain.com 

 

Summary of Contents for PFD1 AstiPure

Page 1: ...uarters Factory 41 boulevard des Bouvets E A D A C des Berthilliers F 92741 NANTERRE CEDEX F 71850 CHARNAY LES MACON Tel 33 0 1 55 68 59 59 Tel 33 0 3 85 20 27 00 Fax 33 0 1 55 68 59 68 Fax 33 0 3 85...

Page 2: ...V 1 Trouble shooting V 2 Preventive maintenance V 2 1 Continuous operation V 2 2 Intermittent operation V 3 Comments VI Dismantling and Repair 6 VI 1 How to dismantle VI 2 Examination VI 3 Stripping a...

Page 3: ...The pumping frequency of a bellows pump is much slower than an equivalent diaphragm pump and results in an extended life for the bellows Pulsation dampers with wetted parts in TEFLON PFA and PTFE are...

Page 4: ...ump must be positioned on its feet If not the check valves will not seat correctly and the pump may malfunction III 3 Connections III 3 1 Air Nitrogen connection The pump must be connected to a clean...

Page 5: ...are tight The air nitrogen supply is dry clean and between 29 and 72 5 PSI 2 and 5 bar The inlet and outlet fluid connections are correctly fitted and tight IV Applications IV 1 Chemical compatibilit...

Page 6: ...bout 135 strokes min The following should NOT be part of the system Do not connect the pump inlet or outlet with air nitrogen or liquid under pressure Lubricated and or wet air nitrogen Air supply tub...

Page 7: ...bellow O ring P N 2725 Body O ring P N 2739 Manifold O ring P N 2745 Lip seal P N 2711 PFD or 2711A PFS PTFEsleeves P N 7220 Silencers P N 7185 Ball valves P N 2712 V 2 2 Intermittent operation If the...

Page 8: ...o drawing APP 1 REF to visualize marks and part numbers quoted hereafter VI 3 1 Replacing the shuttle valve The valve is easily removed from the outside 1 Unscrew the 2 fastening screws take care not...

Page 9: ...P N KPFD1 as follows Each of the 4 shaft rings P N 7135F is composed of two parts one O ring and one sleeve Figure 1 O rings can be installed with the O ring positioning tool P N 1641 To install the r...

Page 10: ...eeve insertion tool P N 2680 Figure 4 While holding the O ring positioning tool P N 1641 against the plate place the sleeve insertion tool P N 2680 into the other side and use the push button to relea...

Page 11: ...uctions but in reverse order VI 3 4 Replacing the PTFE sleeves Follow the same procedure as for VI 3 3 until 14 after replacing the composite rings remove the PTFE sleeves P N 7220 from the groove wit...

Page 12: ...repair will be proposed to you and the pump will be returned to you within one week from date of its acceptance VII Warranty SGPPL ASTI pumps and accessories are warranted for all parts and labor aga...

Page 13: ...TH INSERT 2 2 2613S PFS1 BELLOW ROUNDED SPIRES WITH INSERT 2 2 2615 CENTRAL SHAFT 1 1 1 1 2701 SHUTTLE VALVE 1 1 1 1 2701F SHUTTLE VALVE PE UHMW SHUTTLE 1 1 1 1 2706 BODY RING 2 2 2 2 2706T ETFE BODY...

Page 14: ...LVE 10 4 4 2725 VITON BELLOW O RING 2 2 2729 C PEEK 5x50 PLATE SCREW 2 2739 FEP BODY O RING 2 2 2745 FEP MANIFOLD O RING 4 4 7135F SHAFT COMPOSITE O RING 4 4 7139 VITON PNEUMATIC O RING 6 7185 1 4 EXH...

Page 15: ...ORMANCE PLASTICS ASTI 41 Boulevard des Bouvets 92000 Nanterre France Tel 33 0 1 55 68 59 59 Fax 33 0 1 55 68 59 68 http www astipure com TM 24 09 01 V rifi par En date du 2x 7185 2x L B 4x 1028 2x E 4...

Page 16: ...A Shuttle valve B Bladed plate C Tapped plate D Central shaft E Stopper F Bellow G Manifold O Ring H Body O Ring I Lip seal J Manifold K Pump body L Body ring M Nut PR S 1 210 K F IMPORTANT The follow...

Page 17: ...I I I 41 Boulevard des Bouvets F 92741 Nanterre Cedex FRANCE Tel 33 0 1 55 68 59 59 Fax 33 0 1 55 68 59 68 Dessin par Valid par DATE DESIGNATION FM 02 05 00 Pump ASTIPURE 1 APP 1 EXT 00 134 8mm 5 31...