Thank you for selecting a SAINT-GOBAIN PERFORMANCE PLASTICS ASTI model PFD1 AstiPure™

 

pump, series 2 (or PFS1: slurry applications). 
 

I – General  

 

I.1 – Introduction 

 
The Model PFD/PFS is a pneumatically operated 

TEFLON

®

 pump. There are no internal or external 

metal parts. 
The pump is designed for handling corrosive, inflammable and sterile fluids. It meets the requirements of 
the semiconductor, pharmaceutical and chemical industries. 
 

I.2 – Materials 

 

All wetted parts are manufactured in 

TEFLON

®

 PFA HP and PTFE. 

Other parts are made of high-tech plastics such as PVDF, PEEK etc. 

There are no metal parts.

 

 

I.3 – Operation 

 
The pump is pneumatically operated; two bellows joined by a central shaft reciprocate horizontally. The 
suction and delivery strokes alternate from one side of the pump to the other.  
The pump is self-priming and has four balls, which seat on

 

lip seals (check valves). 

The pumping frequency of a bellows pump is much slower than an equivalent diaphragm pump and 
results in an extended life for the bellows. 
Pulsation dampers with wetted parts in 

TEFLON

®

 PFA and PTFE are available as an option. This 

dampens the pulse by approximately 65 to 80%. The pulsation damper for the PFD1/PFS1 pump is 
AMC1/AMS1. 
 

I.4 – Pump Data 

 
Flow rate 

2.5 GPM (600 l/h) 

Discharge pressure 

58 PSI max. (4 bar) 

Suction head 

10 feet water column (3 m) 

Max. air consumption 

6 SCFM (10 m³/h) NTP  

Connections 

3/8”x1/2” or 10x13 mm 

TEFLON

®

 flared tube or 1/2” MNPT thread. 

Air connection 

1/4" I/D gas female thread 

 

Tubing 

3/32”x5/32” (2.5x4 mm) maximum 

 

10 feet (3 m) < length < 20 feet (6 m) 

Weight 

4.5 lbs (2 kg) 

 
Also available three larger capacity pumps with optional pulsation dampers: 
 
PFD2/PFS2 

Flow rate 5 US GPM (20 l/min) 

AMC2/AMS2 

PFD3/PFS3 

Flow rate 12.5 US GPM (50 l/min) 

AMC3/AMS3 

PFD4/PFS4 

Flow rate 25 US GPM (100 l/min) 

AMC4/AMS4 

 

II – Quick checklist 

 

II.1  – Shipment 

 
Pumps are cleaned and assembled in our clean room, then double sealed in plastic bags to ensure they 
are not contaminated in transit. They are then packed in cartons with Polyethylene protection. 

Summary of Contents for PFD1 AstiPure

Page 1: ...uarters Factory 41 boulevard des Bouvets E A D A C des Berthilliers F 92741 NANTERRE CEDEX F 71850 CHARNAY LES MACON Tel 33 0 1 55 68 59 59 Tel 33 0 3 85 20 27 00 Fax 33 0 1 55 68 59 68 Fax 33 0 3 85...

Page 2: ...V 1 Trouble shooting V 2 Preventive maintenance V 2 1 Continuous operation V 2 2 Intermittent operation V 3 Comments VI Dismantling and Repair 6 VI 1 How to dismantle VI 2 Examination VI 3 Stripping a...

Page 3: ...The pumping frequency of a bellows pump is much slower than an equivalent diaphragm pump and results in an extended life for the bellows Pulsation dampers with wetted parts in TEFLON PFA and PTFE are...

Page 4: ...ump must be positioned on its feet If not the check valves will not seat correctly and the pump may malfunction III 3 Connections III 3 1 Air Nitrogen connection The pump must be connected to a clean...

Page 5: ...are tight The air nitrogen supply is dry clean and between 29 and 72 5 PSI 2 and 5 bar The inlet and outlet fluid connections are correctly fitted and tight IV Applications IV 1 Chemical compatibilit...

Page 6: ...bout 135 strokes min The following should NOT be part of the system Do not connect the pump inlet or outlet with air nitrogen or liquid under pressure Lubricated and or wet air nitrogen Air supply tub...

Page 7: ...bellow O ring P N 2725 Body O ring P N 2739 Manifold O ring P N 2745 Lip seal P N 2711 PFD or 2711A PFS PTFEsleeves P N 7220 Silencers P N 7185 Ball valves P N 2712 V 2 2 Intermittent operation If the...

Page 8: ...o drawing APP 1 REF to visualize marks and part numbers quoted hereafter VI 3 1 Replacing the shuttle valve The valve is easily removed from the outside 1 Unscrew the 2 fastening screws take care not...

Page 9: ...P N KPFD1 as follows Each of the 4 shaft rings P N 7135F is composed of two parts one O ring and one sleeve Figure 1 O rings can be installed with the O ring positioning tool P N 1641 To install the r...

Page 10: ...eeve insertion tool P N 2680 Figure 4 While holding the O ring positioning tool P N 1641 against the plate place the sleeve insertion tool P N 2680 into the other side and use the push button to relea...

Page 11: ...uctions but in reverse order VI 3 4 Replacing the PTFE sleeves Follow the same procedure as for VI 3 3 until 14 after replacing the composite rings remove the PTFE sleeves P N 7220 from the groove wit...

Page 12: ...repair will be proposed to you and the pump will be returned to you within one week from date of its acceptance VII Warranty SGPPL ASTI pumps and accessories are warranted for all parts and labor aga...

Page 13: ...TH INSERT 2 2 2613S PFS1 BELLOW ROUNDED SPIRES WITH INSERT 2 2 2615 CENTRAL SHAFT 1 1 1 1 2701 SHUTTLE VALVE 1 1 1 1 2701F SHUTTLE VALVE PE UHMW SHUTTLE 1 1 1 1 2706 BODY RING 2 2 2 2 2706T ETFE BODY...

Page 14: ...LVE 10 4 4 2725 VITON BELLOW O RING 2 2 2729 C PEEK 5x50 PLATE SCREW 2 2739 FEP BODY O RING 2 2 2745 FEP MANIFOLD O RING 4 4 7135F SHAFT COMPOSITE O RING 4 4 7139 VITON PNEUMATIC O RING 6 7185 1 4 EXH...

Page 15: ...ORMANCE PLASTICS ASTI 41 Boulevard des Bouvets 92000 Nanterre France Tel 33 0 1 55 68 59 59 Fax 33 0 1 55 68 59 68 http www astipure com TM 24 09 01 V rifi par En date du 2x 7185 2x L B 4x 1028 2x E 4...

Page 16: ...A Shuttle valve B Bladed plate C Tapped plate D Central shaft E Stopper F Bellow G Manifold O Ring H Body O Ring I Lip seal J Manifold K Pump body L Body ring M Nut PR S 1 210 K F IMPORTANT The follow...

Page 17: ...I I I 41 Boulevard des Bouvets F 92741 Nanterre Cedex FRANCE Tel 33 0 1 55 68 59 59 Fax 33 0 1 55 68 59 68 Dessin par Valid par DATE DESIGNATION FM 02 05 00 Pump ASTIPURE 1 APP 1 EXT 00 134 8mm 5 31...

Page 18: ...re PFD1 PFS1 pump flow rate characteristics 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 50 150 250 350 450 550 650 750 Flow rate l h Discharge head bar Air supply 5 bar Air supply 4 bar Air supply 3 bar Air supply...

Page 19: ...SG G G GP P P PP P P PL L L L A A A AS S S ST T T TI I I I 41 Boulevard des Bouvets F 92741 Nanterre Cedex FRANCE Tel 33 0 1 55 68 59 59 Fax 33 0 1 55 68 59 68 VANNE DE REGLAGE VALVE VANNE D ARRET STO...

Reviews: