background image

10.06

(256)

5.19 (MAX)

(127)  (MAX)

5.19 (MAX)

(127)  (MAX)

4.00

(102)

0.84

(21)

10.06

(256)

4.00

(102)

0.84

(21)

0.75

(19)

5.84

(148)

2.06

(52)

1.84

(47)

2.72

(69)

2.00

(51)

12.88

(328)

12.88

(328)

12.88

(328)

2.06

(52)

1.84

(47)

0.75

(19)

5.84

(148)

2.72

(69)

2.00

(51)

PRODUCT DATA

Pump Design

......................Air Operated Double Diaphragm

Wetted Parts

Diaphragm Material

..Santoprene

®

or Viton

®

Check Valve Seat Material

..Santoprene

®

or Viton

®

Housing and check valve material

................Polypropylene (Glass Reinforced)

Springs

........................................Hastelloy

Mounting Brackets and Manifolds

..................Polypropylene

Ports

..........................................Gas Inlet/Outlet 1/4” (6.3 mm)

Product Inlet/Outlet (Dual) - 1/2” NPT (12.7 mm)

Product Inlet/Outlet (Quatro) - 3/4” NPT (19.1 mm)

Net Weight 

Dual ..............................3.5 Pounds (1.59kg)
Quatro ..........................7.0 Pounds (3.18kg)

®

A registered trade mark of Monsanto Co.

®

A registered trade mark of I.E. DuPont Co

.

PERFORMANCE SPECIFICATIONS

PUMP

Liquid Temperature

Min  ............................................40°F (4.4°C)

............................Max ........................................120°F (48.9°c)

Priming

..............Dry  ..........................................15 ft. (4.5 m)

............................Wet  ..........................................20 ft. (6.1 m)

Flow Rates 

........Max  ........(Dual) Up to 10 GPM (37.8 L/min)

Flow Rates 

........Max  ....(Quatro) Up to 20 GPM (75.6 L/min)

Gas Supply Pressure 

................20 to 100 PSI (1.4 to 6.9 bar)

Noise Level

........Max ......................................................90dB

DESCRIPTION

FLOJET Industrial G-57 Series Pumps are designed for
general  commercial  and  industrial  applications.  These
pumps are constructed from a selection of materials for
handling a broad range of chemicals.

Allowed fluids for

Not Allowed fluids for

Santoprene 

®

materials

Santoprene 

®

materials

Potable Water, Acids

Oils, Solvents,Soaps with 

Alkaline, Soaps

Solvents, D-Limonene,

Alcohols, Ketones

Aromatic Hydrocarbons

Allowed fluids for

Not Allowed fluids for

Viton 

®

materials

Viton 

®

materials

Oils, Solvents, D-Limonene,

Ketones, Acetones, 

Aromatic & Halogenated

Automotive Brake Fluid,

Hydrocarbons, Acids

Ammonia, Ethanol

DIMENSIONAL DRAWING

Inches (millimeters)

Consult factory if precise details are required.

40

(2.8)

20

(1.4)

60

(4.1)

80

(5.5)

100

(6.9)

Flow in GPM (l/min)

*Indicates Air Inlet Pressure in PSI

Dual (10 GPM)

(Model G257XXX)

Quatro (20 GPM)

(Model G457XXX)

H

e

a

d

 P

re

s

s

u

re

 i

n

 P

S

(B

a

r)

0

5.0

(18.9)

10.0

(37.8)

0

5.0

(18.9)

10.0

(37.8)

15.0

(56.6)

20.0

(75.5)

100*

80*

60*

40*

20*

100*

80*

60*

40*

20*

INSTALLATION & OPERATION INFORMATION FOR MODELS G257XXX AND G457XXX

Dual Pump (Model G257xxx)

Quatro Pump (Model G457xxx)

DUAL (10 GPM) AND 

QUATRO (20 GPM) 

AIR OPERATED DIAPHRAGM PUMPS 