MOUNTING & PLUMBING

Flojet’s  10  GPM  Dual  and  20  GPM  quatro  pumps  should  be
mounted in a dry and adequately ventilated area. Since these
are self priming pumps they can be mounted several feet from
the  tank  above  or  below  the  liquid  level.  These  can  be
mounted  either  on  the  floor  or  on  the  wall.  For  most
applications, mounting at no more than 4 feet above the liquid
level. this is not a submersible pump.

Secure pump system to desired fixture by screws through the
baseplate of the pump bracket.

Use flexible hoses to avoid excess stress on the pump ports.
Do not crimp or kink hoses. All hoses should be the same size
as  the  pump  port  fittings.  Fittings  must  be  compatible  with
liquid being pumped. Use plastic fittings. Avoid sharp bends
that  could  restrict  flow  or  cause  hose  to  collapse  under
vacuum. Use reinforced hoses.

Make sure gas regulator is set at zero. Use reinforced 1/4” hose
to connect to gas supply from regulator to the ‘Gas In’ port.
The exhaust could be vented to atmosphere or through a muffler. 

Use  of  check  valves  (especially  with  a  cracking  pressure  >
2psi) could interfere with priming capability of the pumps. Use
a minimum 40 mesh strainer before the pump inlet.

OPERATION

At start-up, regulate gas pressure to desired setting. For most
installations  20  PSI  (1.4  bar)  inlet  will  be  adequate,  although
DO NOT go below 20 PSI. Pump will operate according to air
supply.  Flow  and  pressure  can  be  adjusted  by  increasing  or
decreasing  gas  pressure  to  accommodate  varying  product
viscosities,  length  of  lines  or  other  installation  conditions.
Review flow curves located on page 1 for further assistance.
High  viscosity  fluids  and  hose  length  will  limit  priming
distance.

IF  PUMP  IS  T0  BE  USED  IN  HIGH  FLOW,  LOW

PRESSURE APPLICATIONS, ADJUST GAS PRESSURE TO 20
PSI (1.38 BAR) ABOVE DISCHARGE PRESSURE.

CAUTION:  DO  NOT  EXCEED  100  PSI  (6.9  bar)  GAS  INLET
PRESSURE.

CONTINUOUS  OPERATION  AT  120°F  (48.9°C)  WILL
REDUCE PUMP LIFE.

AIR MUST BE DRY AND OIL FREE.

Compressors  must  have  dryers  and/or  a  water  separator  in
the air distribution system. Pumps that fail due to water in the
air chamber will not be covered under the limited warranty.

GENERAL SAFETY INFORMATION

Protect  yourself  and  others  by  observing  all  safety
information.  Follow  all  safety  codes  and  the  Occupational
Safety and Health Act (OSHA).

DO NOT PUMP GASOLINE OR FLAMMABLE

LIQUIDS OR USE WHERE FLAMMABLE

VAPORS ARE PRESENT.
If used with C0

2

or N

2

be sure the area is well

ventilated.

CAUTION:

Do not clean or service FLOJET pumps, hoses or valves while
the  system  is  pressurized.  Plastic  CO

2

air  inlet  ports  do  not

have  a  check  valve.  Prior  to  cleaning  or  servicing,  purge  the
pump by carefully tilting the pump so ports are facing up and
remove  suction  line  from  source.  Turn  air  off  and  disconnect
air inlet line. (Brass air inlet ports have a check valve)

PREVENTIVE MAINTENANCE TIPS 

Tips to help prolong your pump’s life.

• If pumping liquid other than water. pump should be flushed

with water (if applicable) after every use.

• Before freezing conditions occur. pump must be liquid free.

• If mounting pump in an outdoor environment. shield pump

from  environmental  extremes  (i.e.  sunlight.  water  from
washdown spray, rain, etc.).

• When using an air compressor. use an inline air dryer before

the pump to limit water build-up.

10 GPM (DUAL) AND 20 GPM (QUATRO)
DISASSEMBLY PROCEDURE

Remove  the  gas  (AIR  IN)  lines  and  liquid  suction  and
discharge  lines  from  the  Dual  or  Quatro  pump  systems.  You
can then disconnect the suction and discharge manifolds from
the pumps. For the Dual pump systems this is accomplished
simply by sliding the retainer clips on the pump and pulling the
manifolds  away  form  the  pump.  For  Quatro  pump  systems
you will have to take off the screws holding the pumps on any
one  side.  That  will  create  room  for  the  pumps  to  be  pulled
away from the manifold after sliding the retainer clips on these
pumps. The AIR IN fitting can also be disengaged from each
of the pumps similary by sliding the retainer clip. The muffler
also can be removed by sliding its retainer clip.

ASSEMBLY PROCEDURE

In order to replace a pump you will then need to remove the
screws  holding  the  pump  to  the  bracket. 

PLEASE  MAKE

ABSOLUTELY SURE THAT YOU REPLACE A PUMP WITH
ANOTHER  PUMP  WITH  EXACTLY  THE  SAME  PART
NUMBER. EVEN THOUGH THE PUMPS LOOK SIMILAR ON
THE OUTSIDE, THE INTERNAL PARTS ARE DIFFERENT.

When putting the system back together you go in the reverse
order by putting the pumps together first and the fittings in the
end. You need to make sure that each fitting/manifold port has
the O-ring in the groove and the retainer clip is pushed back
in  the  lock  position.  Also  make  sure  the  pumps  are  securely
fastened  to  the  bracket.  Ensure  you  have  proper  sealing  on
the  fittings  that  are  threaded  into  the  ports.  Then  you  may
connect the gas/air in and liquid tubes.

If  you  want  to  repair  the  G-57  pumps,  please  refer  to  the
instructions on page 3 of this manual .

WARNING

FLEXIBLE

HOSE

RIGID

PIPE