6-4
F37
AC STICK welding -
switchover of
characteristics
OFF/ON
OFF
Sets the static characteristics in AC STICK welding
mode.
OFF: Constant voltage characteristics
ON: Drooping characteristics
—
F38
AC STICK welding -
adjustment of drooping
characteristics current
change amount
-100 to 100
0 (V)
Set the current change amount when switchover of
characteristics is set to "ON” for drooping
characteristics.
—
F39
Current display adjustment
(GAIN)
-20 to 20
0 (%)
Adjusts the current values displayed on the digital
meter.
—
F40
Current display adjustment
(OFFSET)
-20 to 20
0 (A)
F41
Voltage display adjustment
(GAIN)
-20 to 20
0 (%)
Adjusts the voltage values displayed on the digital
meter.
—
F42
Voltage display adjustment
(OFFSET)
-2.0 to 2.0
0.0 (V)
F43
CAN ID
1 to 16
1
Sets CAN ID numbers to be used in the PC
monitoring system, etc.
—
F44
Reading welding conditions
with remote control
OFF/ON
OFF
Sets whether to read "1" to "10" of the welding
conditions stored on the memory via the analog
remote control:
OFF: Not to read
ON: Reads
—
F45
Special crater
sequence
OFF/ON
OFF
Sets the initial current and crater current as applied
for a fixed period of time regardless of the torch
switch operation:
OFF: Not applied
ON: Applied (Time set by F46 and F47 is applied)
○
F46
Special crater sequence
initial time
0.0 to 10.0
0.0 (s)
Sets initial time in the special crater sequence.
(available when "ON" is selected in F45)
○
F47
Special crater sequence
crater time
0.0 to 10.0
0.0 (s)
Sets crater time in the special crater sequence.
(available when F45 is enabled)
○
F48
Setting change of current
value (initial current, crater
current)
OFF/ON
OFF
When "CRATER ON" is selected, sets the current
value of the initial current and crater current in the
percentage based on the current value of the
welding condition.
OFF: invalid
ON: settable with percentage
—
F49
Setting of current value
(initial current)
10 to 300
100 (%)
Sets the current value of the initial current in the
percentage based on the current value of the
welding condition.
—
F50
Setting of current value
(crater current)
10 to 300
100 (%)
Sets the current value of the crater current in the
percentage based on the current value of the
welding condition.
—
F51
No function
OFF (fixed)
OFF
No functions are provided.
—
F52
Data type of data log
function
0 to 1
0
Sets sample data on the data log:
0: No sampling
1: Current command / welding current / welding
voltage
○
F53
Data log function
sampling speed
1/2/3
2
Sets sampling interval of the data log function.
1: 10 ms
2: 100 ms
3: 1 s
—
F54
No function
OFF (fixed)
OFF
No functions are provided.
—
No.
Function Name
Setting range
Initial value
Explanation
Memory
Summary of Contents for Welbee WB-A350P
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO ...
Page 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Page 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Page 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Page 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Page 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...